Julie,
Rich Hastings with Public Works completed a second site investigation for compliance with the drainage
culvert work performed at the USR-1614 SemCrude facility. Attached are his findings. Please direct your
inquiries on this issue to the Public Works office. Thank you.
Kim Ogle
Weld County Planning Services-Greeley Office
1555 North 17th Avenue I Greeley CO 80631 I kooleeco.weld,co.us
T 970.356.4000 x 3549 l F:970 304 6498
From: Richard Hastings
Sent: Tuesday, April 13, 2010 11:45 AM
To: Kim Ogle
Cc: David Bauer; Donald Carroll; Josh Holbrook; Nick Marquez; Tom Parko
Subject: (AmUSR-1614) SemCrude, LP (Re-inspection of Drainage Features adjacent to WCR 30)
Kim,
Please find attached, an updated memo reflecting Public Works findings
during yesterday' s (4-12-10) site inspection of the above-mentioned
facility.
Let me know if you have any questions or require further information.
Thanks,
Rich Hastings
Weld County Public Works/Engineering Dept .
1111 H Street (Site Address)
P.O. Box 758 (Mailing Address)
2010-0821
(Il'It AIG z./. /9_ ,2O/c) 1 P2- 9/S
Greeley, CO 80632-0758
Office: (970) 304-6496 EXT. 3727
Cell : (970) 381-3767
rhastings@co .weld.co.us
2
Th MEMORANDUM
r t
ft 44.44111 TO: Kim Ogle, Planning Services DATE: 13-April-2010
IllFROM: Richard A. Hastings, Weld County Public Works
O
• SUBJECT: (AmUSR-1614) - SemCrude, LP (Re-inspection of Drainage
COLORADO Features Adjacent to WCR 30)
Weld County Public Works Department performed a site inspection on 4/12/10, at the above
mentioned site, and has observed the following:
g
• No filter fabric was found to be installed, under the rip rap, during the inspection. Sheet #1 of
approved Tetra Tech Developed Drainage Plans (Job #: 80-5291 .001 ) shows rip rap at Driveway and
Site Culverts will be installed "WITH FILTER FABRIC AND 6" OF TYPE II BEDDING".
• The rip rap installed on the outlet/east side of the Site Culvert is higher in elevation than the culvert
outlet. (See Example Photos #1 & #2 Below)
I
Culvert .. .
j� •. .
`b it: it ar 'L
- .;43;_
. .
I -IN _
_ t • �l _ - 4, J .ar '� `mss '•��r.: - -- - : --- ,
+ w ! '� iii: _ r w-�- /'ot,4,1/4 . ��y.GIB.inkik '• .. _ ..
.•
> _,. ... -N.
. - -, 'V toesTs-s_ asats Aftw•k -...,
. . . _ . _ --,"
, ._, 44, _Y - , .....;%14,
is
..
Photo#1- Site Culvert (outlet, cast side of exit) Photo#2- Site Culvert-(ground level, looking
east, down slope from culvert outlet)
Recommendation
Rip rap at both the Driveway and Site Culverts, as per specifications of above-mentioned drainage plans,
was not installed properly and so cannot be accepted. No filter fabric was observed under the riprap. The
proper flow-line from the Site Culvert needs to be re-established to allow for adequate drainage of run-
off and the riprap blocks the outlet.
pc: Dave Bauer, Weld County Public Works
Don Carroll, Weld County Public Works
Nick Marquez, Weld County Public Works
AmUSR- 1614
MAPLANNING - DEVELOPMENT REVIEW\USR-Use by Special Review\AmUSR-1614 - SemCrude\USR-1614 memo(4-13-10).docz
Hello