HomeMy WebLinkAbout20100821.tiff Esther Gesick From: Kim Ogle Sent: Tuesday, April 13, 2010 12:38 PM To: 'Cozad, Julie; 'Nora, Pam' Cc: Esther Gesick; Tom Parko; Kim Ogle Subject: FW: (AmUSR-1614) SemCrude, LP (Re-inspection of Drainage Features adjacent to WCR 30) Attachments: USR-1614 memo(4-13-10).pdf Julie, Rich Hastings with Public Works completed a second site investigation for compliance with the drainage culvert work performed at the USR-1614 SemCrude facility. Attached are his findings. Please direct your inquiries on this issue to the Public Works office. Thank you. Kim Ogle Weld County Planning Services-Greeley Office 1555 North 17th Avenue I Greeley CO 80631 I kooleeco.weld,co.us T 970.356.4000 x 3549 l F:970 304 6498 From: Richard Hastings Sent: Tuesday, April 13, 2010 11:45 AM To: Kim Ogle Cc: David Bauer; Donald Carroll; Josh Holbrook; Nick Marquez; Tom Parko Subject: (AmUSR-1614) SemCrude, LP (Re-inspection of Drainage Features adjacent to WCR 30) Kim, Please find attached, an updated memo reflecting Public Works findings during yesterday' s (4-12-10) site inspection of the above-mentioned facility. Let me know if you have any questions or require further information. Thanks, Rich Hastings Weld County Public Works/Engineering Dept . 1111 H Street (Site Address) P.O. Box 758 (Mailing Address) 2010-0821 (Il'It AIG z./. /9_ ,2O/c) 1 P2- 9/S Greeley, CO 80632-0758 Office: (970) 304-6496 EXT. 3727 Cell : (970) 381-3767 rhastings@co .weld.co.us 2 Th MEMORANDUM r t ft 44.44111 TO: Kim Ogle, Planning Services DATE: 13-April-2010 IllFROM: Richard A. Hastings, Weld County Public Works O • SUBJECT: (AmUSR-1614) - SemCrude, LP (Re-inspection of Drainage COLORADO Features Adjacent to WCR 30) Weld County Public Works Department performed a site inspection on 4/12/10, at the above mentioned site, and has observed the following: g • No filter fabric was found to be installed, under the rip rap, during the inspection. Sheet #1 of approved Tetra Tech Developed Drainage Plans (Job #: 80-5291 .001 ) shows rip rap at Driveway and Site Culverts will be installed "WITH FILTER FABRIC AND 6" OF TYPE II BEDDING". • The rip rap installed on the outlet/east side of the Site Culvert is higher in elevation than the culvert outlet. (See Example Photos #1 & #2 Below) I Culvert .. . j� •. . `b it: it ar 'L - .;43;_ . . I -IN _ _ t • �l _ - 4, J .ar '� `mss '•��r.: - -- - : --- , + w ! '� iii: _ r w-�- /'ot,4,1/4 . ��y.GIB.inkik '• .. _ .. .• > _,. ... -N. . - -, 'V toesTs-s_ asats Aftw•k -..., . . . _ . _ --," , ._, 44, _Y - , .....;%14, is .. Photo#1- Site Culvert (outlet, cast side of exit) Photo#2- Site Culvert-(ground level, looking east, down slope from culvert outlet) Recommendation Rip rap at both the Driveway and Site Culverts, as per specifications of above-mentioned drainage plans, was not installed properly and so cannot be accepted. No filter fabric was observed under the riprap. The proper flow-line from the Site Culvert needs to be re-established to allow for adequate drainage of run- off and the riprap blocks the outlet. pc: Dave Bauer, Weld County Public Works Don Carroll, Weld County Public Works Nick Marquez, Weld County Public Works AmUSR- 1614 MAPLANNING - DEVELOPMENT REVIEW\USR-Use by Special Review\AmUSR-1614 - SemCrude\USR-1614 memo(4-13-10).docz Hello