Loading...
HomeMy WebLinkAbout20101853.tiff • PRELIMINARY DRAINAGE REPORT CONQUEST OIL COMPAN7 C-7 FACILITY Prepared for: Conquest Oil Company 8207 W. 20th St., Suite B • Greeley, Colorado 80634 Prepared by: CGRS, Inc. PO Box 1489 Fort Collins, CO April 19, 2010 .�c P.C1�O AEG%st, F. 2 o 4 it O;°� 2010-1853 • PRELIMINARY DRAINAGE REPORT CONQUEST C-7 PRODUCED WATER TREATMENT FACILITY I. General Location and Description A. Location Conquest Oil Company proposes to construct and operate a Produced Water Treatment Facility in Weld County. The proposed site is located in the Southeast 1/4 of the Southeast '/, Section 34, Township 7 North, Range 63 West. Weld County Road 74 is adjacent to the property on the south and Weld County Road 69 is adjacent to the property on the east. Colorado Highway 392 is adjacent to the southeast corner of the property, running diagonally across the southeast corner in a southwest to northeast direction. The nearest open water is Crow Creek, located approximately 1,500-feet southeast of the property, flowing in a southwesterly direction. There is an unnamed tributary to Crow Creek approximately 1,500-feet west of the property, flowing south under WCR 74 to Crow Creek. There are no other major open channels, lakes, streams, irrigation or other water resource facilities within or adjacent to the proposed project site. The surrounding ground is agricultural in nature, and no other • developments or municipalities are in the vicinity. Unincorporated Cornish, Colorado is located east of the proposed project site, across WCR 69 and Colorado State Highway 392. B. Description of Property The proposed project site is approximately 11.09 acres in size configured as shown on the Plot Plan. Native grasses cover the site, and site soils consist of Sandy Loam soils, described as "well drained and somewhat excessively drained, moderately rapidly permeable soils on smooth to dissected plains (Soil Survey of Weld County, Colorado, Northern Part, United States Department of Agriculture Soil Conservation Service and Forest Service, August, 1982). The proposed site is very flat, sloping gently to the southeast at an average slope of approximately 0.4%. There are no major open channels on the proposed project property. The property is owned by Mr. Rodney Wilson (Weld County Parcel No. 071334000004). The proposed project is generally described as a produced wastewater treatment facility that will receive produced water from oil and gas well production facilities in Weld County for treatment and disposal. Produced water will be delivered to the facility by truck where the produced water will be collected from the truck and processed in the • treatment facility. Following treatment to required discharge levels, the treatment Conquest Oil C7 Site Preliminary Drainage Report Page 2 • process effluent will be disposed of by deep well injection at an injection well to be located on the project site. Ownership information for the subject property and for properties within 200 feet of the property is provided on the Vicinity Map. There are no irrigation facilities on or within 200 feet of the subject property. Five (5) soil borings were advanced into the subsurface on March 18, 2010 to describe both soils and groundwater characteristics at the property. Boring locations are depicted on the Plot Plan provided with the USR Permit Application. As shown in the boring logs (Appendix A), the soils are generally described as fine to very fine grained sandy silt overlying fine to medium grained sand at depths of 8 to 10 feet below ground surface (bgs). Groundwater was encountered in the borings at depths ranging from 17.8 feet to 19.5 feet bgs. Soil and groundwater quality samples were collected from borings TH-3, TH-4, and TH-5 and delivered to Technology Laboratory in Fort Collins for analysis. The soil samples were analyzed for benzene, toluene, ethylbenzene, total xylenes (BTEX), gasoline range organics (GRO — also referred to as Total Volatile Petroleum Hydrocarbons or TVPH), and diesel range organics (DRO — also referred to • as Total Extractable Petroleum Hydrocarbons or TEPH). Groundwater quality samples were analyzed for BTEX. Analytical results show non-detectable levels for the soil samples for all constituents sampled. Analytical results for the water samples show a total xylenes concentration in the sample fromTH-3 of 0.002 mg/L (method detection level is 0.001 mg/L); all other constituents are documented at less than detection levels. Tables 1 and 2 present Soil Analytical Data and Groundwater Analytical Data, respectively. Furthermore, geotechnical soil samples were obtained from soil borings TH-1 through TH-3 to provide geotechnical information necessary for facility engineering/design. II. Drainage Basins and Sub-Basins A. Major Basin Description The Weld County Master Drainage Plan does not encompass the area of the proposed project because no floodplain or floodway exists in this area. Additionally, a database search for FEMA Flood Insurance Rate Maps (FIRM) in Weld County indicated that there is an unpublished FIRM Map Panel (08026600525c) which covers the subject property area. This is an unpublished map panel because there is no floodplain in this • Conquest Oil C7 Site Preliminary Drainage Report Page 3 • area. Accordingly, no 100-year floodplain or floodway exists in this area that could affect the subject property. Surface topography on and around the subject property is extremely flat, gently sloping to the southeast at an approximate slope of 0.4%. The Plot Plan provides on-site contours at 1-foot vertical intervals, and shows both existing contours and proposed contours as required to accomplish adequate site drainage, including the on-site storm water detention pond. Major drainage basin characteristics are summarized in Appendix B. B. Sub-Basin Description The subject property and adjacent properties historically drain to the south/southeast to Crow Creek located approximately 1,500 feet to the southeast of the property. Crow Creek flows in a southwesterly direction. The subject property slopes gently to a 15- inch diameter culvert in the southeast corner of the property under Weld County Road 69, and thence across the abandoned Union Pacific Railroad right of way to a 24-inch diameter culvert under Colorado State Highway 382, discharging to Crow Creek approximately 1,500 feet to the southeast. Crow Creek flows to its confluence with the • South Platte River approximately 10 miles to the southwest. Off-site drainage flow patterns include an unnamed intermitent tributary to Crow Creek located approximately 1,500 feet west of the property that flows to the south. There is a slightly-defined drainage divide approximately 350 feet west of the subject property. Accordingly, drainage from the subject property and the ground directly to the west is to the southeast to the aforementioned 15-inch diameter culvert under WCR 69. As indicated above, the overall site is very flat and produced correspondingly slow runoff patterns. This flat slope coupled with fairly permeable soils, generally consisting of "8 to 10-feet of silty sand over slightly silty to gravelly sands to the depths explored (CTL Thompson, Geotechnical Investigation, Conquest Oil C7T, April 1, 2010)," result in minimal runoff production in response to most precipitation events. Due to the soils that are present in the area and the very flat slopes, both on-site and up-gradient of the proposed site, off-site drainage flow onto the subject property are not expected. In fact, there is a local high point in the northeast portion of the subject property from which on- site drainage flows from the subject property off-site to the north. • Conquest Oil C7 Site Preliminary Drainage Report Page 4 • III. Drainage Design Criteria A. Development Criteria Reference and Constraints As stated above, the Weld County Master Drainage Plan does not encompass the subject property or adjacent properties because there are no mapped flood plains or floodways in the vicinity. No other previous drainage study of the subject property has been done. Accordingly, the proposed drainage design will not be influenced nor will it have an influence on previous drainage studies for the area. Existing site constraints of very flat sloping ground influence the drainage design by the requirement of importing a modest amount of fill material in order to establish positive drainage of the site to the aforementioned 15-inch culvert in the southeast corner of the property. No streets, utilities, existing structures, or irrigation ditches are present on-site or in the immediate area that would pose constraints on the proposed drainage plan. B. Hydrologic Criteria An on-site storm water detention basin is proposed based on the Urban Drainage and Flood Control District (UDFCD) spreadsheets to calculate peak runoff using the Rational Method. The detention pond is sized to contain runoff from the 100-year, 1-hour • precipitation event. The detention pond must also provide for a release rate at the historical 5-year, 1-hour precipitation event runoff rate for the site under undeveloped conditions. The UDFCD spreadsheet using the Rational Method was also used to predict the 5-year 1-hour runoff rate. Copies of the UDFCD spreadsheets for these precipitation events are provided in Appendix B. UDFCD spreadsheets provided include the following: • Map of Colorado Hydrologic Zones showing the project site to be in Hydrologic Zone 1; • Intensity-Duration-Frequency (IDF) Table for Zone One in the State of Colorado; • Area-Weighting for Runoff Coefficient Calculation; • Calculation of Peak Runoff Using Rational Method for the 100-year, 1-hour precipitation event; and • Calculation of Peak Runoff Using Rational Method for the 5-year, 1-hour precipitation event. Rainfall data given on NOAA Atlas 2, Volume III for the 6-hour and 24-hour precipitation events with 2-year, 5-year, 10-year, 25-year, 50-year, and 100-year return period were entered on the UDFCD IDF Table for Zone One in the State of Colorado in order to • develop the1-hour storm rainfall depth. The UDFCD IDF Table is provided in Appendix Conquest Oil C7 Site Preliminary Drainage Report Page 5 • B showing the 5-year and 100-year, 1-hour events rainfall depths of 1.49-inches and 2.86-inches, respectively. Hydrologic data used in the UDFCD model are based on a drainage basin area of 11.09 acres, 45% impervious ground (post-development), Soil Type A, and an area-weighted Runoff Coefficient of 0.27. Model results indicate a 100-year, 1-hour precipitation event peak runoff flowrate of 19.79 cubic feet per second (cfs) and a regional time of concentration (Tc) of 14.44 minutes. The corresponding calculated peak storage volume required to detain the 100-year, 1-hour event is 17,146 cubic feet (cf). In accordance with Weld County requirements, the detention pond must detain the total runoff volume produced by the 100-year, 1-hour precipitation event with a release rate not to exceed the historic 5- year, 1-hour event discharge. Accordingly, the UDFCD spreadsheet was also run for the 5-year event, with the results showing that discharge from this property does not occur during the 5-year event. Accordingly, the detention pond for this project is designed to completely detain a runoff volume of 17,146 cf. C. Hydraulic Criteria • On-site runoff to the proposed detention pond is via sheet flow, and as such no specific channel or ditch exists to deliver surface runoff to the detention pond. Detention pond requirements of Weld County are that an on-site detention pond must detain the total runoff from the 100-year, 1-hour precipitation event while allowing a release rate not to exceed the historic release from the 5-year, 1-hour precipitation event. As shown below, there would be no discharge from the subject property in response to the 5-year 1-hour event. Accordingly, the proposed detention pond does not include outlet works, nor will there be outlet water quality issues. Design flood calculations are based on Urban Drainage and Flood Control District design spreadsheets. IV. Drainage Facility Design A. General Concept The subject property is divided roughly in half, with the western (topographically higher) portion to contain the Conquest C7 project development, and the eastern half to remain open. It is in the eastern, topographically lower, portion of the site where the on-site detention pond will be located. Structural fill material will be imported to the site in order to slightly elevate the Conquest facility buildings and associated other structures and to facilitate site drainage on this very flat property. A detention pond capacity of 17,146 cubic feet will be required to detain runoff from the • 100-year 1-hour event. Construction of the detention pond will require minor Conquest Oil C7 Site Preliminary Drainage Report Page 6 • excavation/earthwork to provide the required capacity. Typical on-site drainage patterns will be split at the entrance road to the facility, with a small amount of on-site runoff flowing off the entry drive to the west to a natural low area along the western property line. The remainder of the property will drain to the on-site detention pond and drain into the subsurface through the relatively porous soils that exist at this location. There are no known off-site runoff considerations and constraints with respect to this project with the exception of the detention pond release rate not to exceed the historic release from the 5-year 1-hour precipitation event from the undeveloped site. Due to existing topography of the site, including a natural "detention pond" in the southeast part of the site, it is shown that there is no discharge from this site in response to the 5-year 1-hour event. B. Specific Details Maintenance of runoff control structures will be minimal. Once native grasses are established within the detention pond, periodic mowing may be required to maintain adequate detention pond volume. • V. Conclusions A. Compliance with the Weld County Code The preliminary drainage design will meet applicable Weld County Code. B. Drainage Concept As proposed, the drainage plan is designed to prevent damage from storm runoff to both the Conquest facility and to adjacent properties. The on-site detention pond will mitigate runoff peaks in response to a 100-year, 1-hour precipitation event. Because there is no Weld County Master Drainage Plan for this area, there are no related recommendations that would influence or be influenced by the proposed project. There will be no affect on irrigation companies or other property owners in the vicinity. The drainage design is based on runoff calculations computed through the UDFCD spreadsheets based on the Rational Method. • Table 1 • SOIL ANALYTICAL DATA Proposed Conquest Oil C-7 Facility WCR 69 and WCR 74 Briggsdale, Colorado CGRS Project: 1-8019-12439aa Depth Benzene Toluene Ethyl-Benzene Xylenes TVPH TEPH Sample ID (ft.) Date (mg/Kg) (mg/Kg) (mg/Kg) (mg/Kg) (mg/Kg) (mg/Kg) TH-3 15 03/18/10 <0.01 <0.01 <0.01 <0.01 <0.5 < 10.0 TH-4 15 03/18/10 <0.01 <0.01 <0.01 <0.01 <0.5 < 10.0 TH-5 15 03/18/10 <0.01 <0.01 <0.01 <0.01 <0.5 < 10.0 MDL 0.01 0.01 0.01 0.01 0.5 10.0 CDLE/OPS-RBSL/TPH Threshold 0.26 170 190 260 500 500 COGCC Allowable Concentration for 0.17 85 100 175 500 500 sensitive area Notes: Concentrations exceeding Tier 1 RBSLs,500 mg/Kg TPH threshold value or CGOCC allowable • concettrations expressed in bold face TVPH=Total Volatile Petroleum Hydrocarbons TEPH=Total Extractable Petroleum Hydrocarbons RBSL=CDLE/OPS-Tier 1 Risk Based Screening Level TPH=total petroleum hydrocarbons MDL=Method Detection Limit • , 1 of 1 TABLE 2 GROUNDWATER ANALYTICAL DATA • Proposed Conquest Oil C-7 Facility WCR 69 and WCR 74 Briggsdale, Colorado CGRS Project: 1-8019-12439aa Depth To Ethyl- Sample ID Date Benzene Toluene Xylenes Water Benzene (ft) (mglL) (mill) (1112/14 (mg✓L) TH-3 03/18/10 20.82 <0.001 <0.001 <0.001 0.002 TH-4 03/18/10 21.72 <0.001 <0.001 <0.001 <0.001 TH-5 03/18/10 22.55 <0.001 <0.001 <0.001 <0.001 COGCC Allowable - 0.005 0.56 0.7 1.4 Concentration for sensitive area MDL - 0.001 0.001 0.001 0.001 Notes: Depth to groundwater is measured from the top of the temporary monitoring well casing,which is • approximately 3 feet above ground surface. Values in bold face exceed MCLs TVPH=Total Volatile Petroleum Hydrocarbons TEPH=Total Extractable Petroleum Hydrocarbons MTBE=Methyl Tertiary Butyl-Ether MCL=Maximum Contaminant Level MDL=Method Detection Limit • 1 of 1 . VI.Appendices A. Soil Boring Logs B. Hydrologic Computations C. Hydraulic Computations . • Appendix A Soil Boring Logs • • C G RS FIELD BOREHOLE LOG BOREHOLE NUMBER TH-1 lirOJECT NUMBER: 1-8019-12439aa TOTAL DEPTH : 10' ROJECT NAME: Conquest Oil C-7 TOP OF RISER:- (wilh cap removed) LOCATION : Briggsdale, CO _ DRILLING CO: Drilling Engineers, Inc. I STATIC WATER LEVELS (BGS)T DRILLING METHOD: HSA Time DRILLER: Sean Date LOGGED BY: TJ Grisel Water Level START: 3/18/2010 COMPLETED: 3/18/2010 Casing Depth 1 C c u a) la Z o Notes LITHOLOGY n a) DEPTH DESCRIPTION (PPm) a) a) c a) a) U E a o E E cti (El io. m ca u) —0 -- ... SANDY SILT: Brown, fine to 7._- very fine-grained, stiff, moist -- (SM) _.__41ill _CAL 1 15 18 18 0.0@2' bgs _ — CAL 2 21 18 18 0.0@4' bgs - - -_ - 5 —. _ SAND: Brown, fine to medium- CAL 3 grained, sub-angular, medium dense, moist(SW) 0.0 @ 9' bgs 16 18 18 -- — 10 lip End of Boring @ 10' bgs I BOREHOLE NUMBER CG RS FIELD BOREHOLE LOG -- TH-2 OJECT NUMBER: 1-8019-12439aa TOTAL DEPTH: 25' ROJECT NAME: Conquest Oil C-7 TOP OF RISER:- (with cap removed) LOCATION: Briggsdale, CO I STATIC WATER LEVELS (BGS) DRILLING CO: Drilling Engineers, Inc. DRILLING METHOD: HSA Time DRILLER: Sean Date I LOGGED BY: TJ Grisel Water Level START: 3/18/2010 COMPLETED: 3/18/2010 Casing Depth C Q) tL v a) a E z 0 Notes LITHOLOGY Z j DEPTH DESCRIPTION cC (PPm) a) a) O 0) W U E E o E E U) cn m Cl) CO — SANDY SILT: Brown, fine to —- very fine-grained, very stiff, -- -.. Ill -- moist(SM) - ., CAL 1 30 18 18 . = -�-5 . 0.0@5' bgs CAL 2 36 18 18 .. _ __ — -10 •-v- SAND: Brown, fine to medium- 0.0 @ 10' bgs grained, sub-angular, very dense, moist to wet @ 15' bgs - to saturated @ 20' bgs; No _ Recovery @ 20'bgs (SW) CAL 3 45 18 18 -15 0.0@15' bgs •1 CAL 4 50+ 18 0 - -20 NM @ 20' bgs Iiiiil I CAL 5 50+ 18 4 ; 0.0 @ 25' bgs .. ...... . .....'1 - -- - -- -- -25 End of Boring @ 25' bgs ' C G RS FIELD BOREHOLE LOG BOREHOLE NUMBER TH-3 "'PROJECT NUMBER:1-8019-12439aa TOTAL DEPTH : 30' PROJECT NAME : Conquest Oil C-7 TOP OF RISER:- LOCATION : Briggsdale, CO (with cap removed) DRILLING CO : Drilling Engineers, Inc. STATIC WATER LEVELS(BGS) DRILLING METHOD : HSA Time 0950 1050 1239 DRILLER: Sean Date 3/18/2010 3/18/2010 3/18/2010 LOGGED BY:TJ Grisel Water Level 20.90 20.84 20.82 START: 3/18/2010 COMPLETED : 3/18/2010 Casing Depth 32.25 c NOTES O WELL WELL Z m a DESCRIPTION (PPm) p DESIGN CONSTRUCTION 0a) g a) w I = E Ea E E I- a LU U) Cl) 0° co cn o - Stick-Up(-3 - ft) • -0 r7,77 r, , , SANDY SILT:Gray,fine-grained, -, stiff,moist(SM) M —-_ .`^ �� CAL 1 18 24 9 --5 - •- - ''-' . 0.0@5'bgs ,.._ - `'. !" 4, -Ait CAL 2 18 24 3 - 4.t.t 01F —-1C P' 4741, SAND:Brown,fine to medium- 0.0 @ 10'bgs '�""".�' _ grained,sub-angular,medium- �5 . it dense, moist to very moist @ 14' s rr t bgs : Natural , 4 - CAL 3 15 24 7 Badcfill 'oi 1 '15 0.0@15' _ SILTY CLAY:Wet, brown,rather bgs;Sample 6=4- `stiff,some fine sand(CL) ! *r'' / Retained for SAND:Brown,fine to medium- Analysis CAL 4 50+ 24 0 grained,sub-angular,medium :'y:: ; —-2C dense to very dense;wet to NM @ 20'bgs : 1"Sch.40 - saturated @ 20'bgs;No recovery : PVC Riser `' ..i: - @ 20'bgs =, 10/20 Silica Sand filter = CAL 5 50+ 24 21 -.2F :•:.:•:•:•:-:-:•:. :- SILTY SAND: Brown,fine-grained, 0.0 @ 25'bgs T T T T T w 1"Schedule T g T.T,T.-1"T.� 40 PVC • _ sub-angular,very dense, T T.r.T T-_ screen#10 T 17. T saturated(SM) T.'T T T.T,: ,SIOt 7"77 T om..T.� :; ' .r T1-TT- r CAL 6 50+ 24 24 0.0@30'bgs TTT.T.:.Tr.- - 3C, `End of Boring @ 30'bgs / C G RS FIELD BOREHOLE LOG BOREHOLE NUMBER TH-4 PROJECT NUMBER:1-8019-12439aa TOTAL DEPTH :20' ROJECT NAME : Conquest Oil C-7 TOP OF RISER : (with cap removed) LOCATION : Briggsdale, CO — Driilin Engineers, STATIC WATER LEVELS(BGS) DRILLING CO: 9 Inc. DRILLING METHOD : HSA Time 1149 1259 DRILLER : Sean Date 3/18/2010 3/18/2010 LOGGED BY:TJ Grisel Water Level 22.25 21.72 START: 3/18/2010 COMPLETED: 3/18/2010 Casing Depth 23.20 c �' • } E E LI:1 Z o NOTES O WELL WELL E ? c DESCRIPTION (ppmj = DESIGN CONSTRUCTION woo w w I H I— E E o E E w cn cn 0, to ca O Stick-Up(-3 _ ft) • _0 r. SANDY SILT:Brown,fine-grained, . .._,,, medium-stiff,moist;Clay lense @ - - 4, 14'bgs(SM) - _ " Y_ '. SB 1 7 18 12 - 'i-` -5 __ 0.0 5'bgs 7.7_77.•- Natural ' -•. "— 7:7-- Backfill w , Y SB 2 14 18 14 _ -._ 1"Sch.40 - -1C — 7-._ PVC Riser _ 0A@10'bgs SB 3 10 18 11 SAND:Brown,fine to medium- - " —-le grained,sub-angular,loose,wet; 0.0 @ 15' • 10/20 Silica :i :: Increasing fine-grained sand with bgs;Sample . Sand fitter depth(SW) Retained for _ Analysis 1"Schedule = - 40 PVC • screen#10 SB 4 32 18 8 0.0 @ 20'bgs . slot 2 End of Boring @ 20'bgs i GRS FIELD BOREHOLE LOG BOREHOLE NUMBER TH-5 "'PROJECT NUMBER:1-8019-124398a TOTAL DEPTH :20' PROJECT NAME: Conquest Oil C-7 TOP OF RISER: (with cap removed) LOCATION : Briggsdale, CO STATIC WATER LEVELS(BGS) DRILLING CO: Drilling Engineers, Inc. DRILLING METHOD : HSA Time 1228 1325 DRILLER: Sean Date 3/18/2010 3/18/2010 LOGGED BY:TJ Grisel Water Level 23.29 22.55 START: 3/18/2010 COMPLETED : 3/18/2010 Casing Depth 23.55 c >. �i m > O WELL WELL ›- E a0i U DESCRIPTION NOTES r p DESIGN CONSTRUCTION l� z' � � � (PP ) 2 a 8 a) a) I i- 0- i— E E ° EE w co kn m (i) O - Stick-Up(-3 ft) • —0 SAND:Brown,fine-grained, ' E - medium dense to dense @ 15'bgs #.•:..':, 'fir _ to very dense @ 20'bgs,moist toi. ::1 ` w r wet @18'bgs to saturated @ 20' T bgs(SP) :,.• _.;,, mac.. :. :: 4:� ky SB 1 9 18 9 ++� — 5 0.0 •:•:-:•:•:•:•:•:•: @ 5'bgs Natural backfill ` a , N..6� .. M. SB 2 9 18 18 - : 1"Sch.40 - —-1C : PVC Riser 0.0@10'bgs - ::j - SB 3 22 18 10 - "j ] -1f 0.0 @ 15 10/20 Silica :: ? - bgs•Sample . Sand filter Retained for - - Analysis : 1"Schedule 40 PVC ` '``' Wscreen#10 0.0 @ 20'bgs : slot SB 4 40 18 12 _ - - 2 / End of Boring @ 20'bgs • Appendix B Hydrologic Computations • • Hydrologic Computations • As required, hydrologic computations make basic assumptions regarding land use on adjacent properties. The property is bordered on the south by Weld County Road 74, on the east by Weld County Road 69, and by undeveloped pasture land on the north and west sides. No developed land exists adjacent to the subject property, with the exception of the area southeast of the subject property. In that direction is the abandoned UP Railroad right-of-way and Colorado State Highway 392. Storm runoff computations are based on the Rational Method as presented in UDFCD spreadsheets. Design storms modeled include the 100-year, 1-hour and the 5-year, 1- hour precipitation events. The site drainage plan is based on the requirement to detain the 100-year, 1-hour precipitation event while maintaining off-site discharge at or below historic discharge from the 5-year, 1-hour precipitation event. UDFCD spreadsheets used include the following: 1. Map of Colorado Hydrologic Zones showing the project site to be in Hydrologic Zone 1; 2. Intensity-Duration-Frequency (IDF) Table for Zone One in the State of Colorado; 3. Area-Weighting for Runoff Coefficient Calculation; 4. Calculation of Peak Runoff Using Rational Method for the 100-year, 1-hour • precipitation event; and 5. Calculation of Peak Runoff Using Rational Method for the 5-year, 1-hour precipitation event. As shown on the UDFCD spreadsheet printouts, the 100-year 1-hour event will produce a peak runoff flowrate of 19.79 cfs at a regional time of concentration (Tc) of 14.44 minutes. The corresponding runoff volume to be detained on-site is 17,146 cf. The 5- year 1-hour precipitation event produces no storm water runoff from this site. • • HYDROLOGIC ZONES IN THE STATE OF COLORADO Identify the hydrologic zone for your project site: Zone 1 , 2, 3 or 4. Zone 1: South Platte, Republican, Arkansas, and Cimarron River Basins Zone 2: San Juan, Upper Rio Grande, Upper Colorado, and Gunnison River Basins, and Green River Basin below Confluence with the Yampa River Zone 3: Yampa and Green River Basins above confluence of Green and Yampa Rivers Zone 4: North Platte River Basins Definition of these four zones: 109 tun 10/ 106 101 104 103 _ 102 1 1 I 1 T 1 _- 1 — _ at 41 rN 1 i I I I— I ,a 1 I II I1 I I r I 1 I I 1 I 1 I I 39 • I 1 i 2 I I I i I I I III -- I I 1& I I I I I I ..') I I COLORADO „a,,,,,,,,•,..,. 10 0 10 70 30 (0 P. i:i •o�.. 1 i.. . .•II<. la�..a.....°.�"�"".nrw..rw1..«. flaw. . /UIIw41 U3 Mrw401.n_____ ..rr4 w. t..n.wd 1S4oNi f-llr nlon. P'w'ari..wr luv 7- mow! fPP:..Iw tr.r.r...�...a r.dw 01Mw I -_L 1 100 roe 10/ 106 101 104 103 1O2 Design Parameters for Various Zones Zone 1 - Hour 2 - hour 3 - Hour a b c d e f m n r q 1 0.2180 0.7090 0.0000 1 .8970 0.4390 -0.0080 0.3420 0.6580 0.5970 0.4030 2 -0.0110 0.9420 p 0.0000 0.4940 0.7550 0.0000 0.3410 0.6590 0.5690 0.4310 3 0.0190 0.7110 0.0010 0.3380 0.6700 0.0010 0.2500 0.7500 0.4670 0.5330 4 0.0280 0.8900 0.0000 0.6710 0.7570 -0.0030 0.2500 0.7500 0.4670 0.5330 Duration in minutes 5.00 10.00 15.00 30.00 • Ratio to one-hr Depth 0.29 0.45 0.57 0.79 UD-RainZone v1 .01 a, ZONES 4/14/2010, 4:32 PM IDF TABLE FOR ZONE ONE IN THE STATE OF COLORADO • Zone 1: South Platte, Republican, Arkansas, and Cimarron River Basins Project: Conquest Oil C7 Site Enter the elevation at the center of the watershed: Elev = 4,713 (input) 1 . Rainfall Depth-Duration-Frequency Table Enter the 6-hour and 24-hour rainfall depths from the NOAA Atlas 2 Volume III in rightmost blue columns Return Rainfall Depth in Inches at Time Duration Period 5-min 10-min 15-min 30-min 1-hr 2-hr 3-hr 6-hr 24-hr (1 ) (2) (3) (4) (5) (6) (7) (8) (9) (10) output output output output output output output input input 2-yr 0.30 0.47 0.59 0.82 1 .04 1 . 16 1 .25 1 .40 1 .70 5-yr 0.43 0.67 0.85 1 . 18 1 .49 1 .61 1 .70 1 .85 2.20 10-yr 0.52 0.80 1 .02 1 .41 1 .79 1 .93 2.03 2.20 2.60 25-yr 0.63 0.97 1 .23 1 .71 2. 17 2.33 2.46 2.65 3.00 50-yr 0.73 1 . 13 1 .44 1 .99 2.52 2.68 2.81 3.00 3.40 100-yr 0.83 1 .28 1 .63 2.26 2.86 3.04 3. 18 3.40 3.80 Note: Refer to NOAA Atlas 2 Volume III isopluvial maps for 6-hr and 24-hr rainfall depths. 2. Rainfall Intensity-Duration-Frequency Table Return Rainfall Intensity in Inches Per Hour at Time Duration Period 5-min 10-min 15-min 30-min 1-hr 2-hr 3-hr 6-hr 24-hr ( 1 ) (2) (3) (4) (5) (6) (7) (8) (9) (10) output output output output output output output output output • 2-yr 3.60 2.80 2.36 1 .64 1 .04 0.58 0.42 0.23 0.07 5-yr 5. 18 4.02 3.40 2.35 1 .49 0.81 0.57 0.31 0.09 10-yr 6.22 4.83 4.08 2.83 1 .79 0.96 0.68 0.37 0. 11 25-yr 7.54 5.85 4.94 3.42 2. 17 1 . 17 0.82 0.44 0. 13 50-yr 8.77 6.81 5.75 3.98 2.52 1 .34 0.94 0.50 0. 14 100-yr 9.94 7.71 6.51 4.51 2.86 1 .52 1 .06 0.57 0. 16 • Copy of UD-RainZone v1 .01a, Z-1 4/14/2010, 4:53 PM • One-Hour Rainfall Depth Design Chart 3.00 _. ---- ------. - -_._ 2.86 ♦ 2.50 - - ------. __ ...t 2.52-♦ 2.17 • 2.00 - _- - 1.79 ♦ u c c a 1.50 — 1A9 4- • 1.00 1.04 • i I 0.50 0.00 2-yr 5-yr 10-yr 25-yr 50-yr 100-yr Return Period • Copy of UD-RainZone v1.01 a, Z-1 4/14/2010, 4:53 PM • Area-Weighting for Runoff Coefficient Calculation Project Title: Conquest C7 Catchment ID : 11 .09 Acre Project Site Illustration LEGEND: Flow Direction I: t s13 Cate in ens Subarea 3 gam . Instructions: For each catchment subarea, enter values for A and C. Subarea Area Runoff Product ID acres Coeff. A C* CA • input input input output C7 Site 11 .09 0.27 2.99 sum: 11 .09 Sum: 2.99 Area-Weighted Runoff Coefficient (sum CA/sum A) = 0.27 *See sheet "Design Info" for inperviousness-based runoff coefficient values. • UD-Rational v1 .02a, Weighted C 4/14/2010, 5:02 PM • CALCULATION OF A PEAK RUNOFF USING RATIONAL METHOD Project Title: Conquest C7 Site Drainage Report • Catchment ID: 11 .09 Acre Projet Site I. Catchment Hydrologic Data Catchment ID = C7 Site Area = 11 .09 Acres Percent Imperviousness = 45.00 NRCS Soil Type = A A, B. C, or D II. Rainfall Information I (inch/hr) = Cl * P1 /(C2 + Td)AC3 Design Storm Return Period, Tr = 100 years (input return period for design storm) C1 = 28.50 (input the value of C1 ) C2= 10.00 (input the value of C2) C3= 0.786 (input the value of C3) P1 = 2.86 inches (input one-hr precipitation--see Sheet "Design Info") III. Analysis of Flow Time (Time of Concentration) for a Catchment Runoff Coefficient, C = 0.43 Overide Runoff Coefficient, C = 0.27 (enter an overide C value if desired, or leave blank to accept calculated C.) 5-yr. Runoff Coefficient, C-5 = 0.27 Overide 5-yr. Runoff Coefficient, C = (enter an overide C-5 value if desired, or leave blank to accept calculated C-5.) Illustration • __—�� , overland Reach 1 flow Reach 2 O Beginning Flow Direction Catchment Reach 3 Boundary NRCS Land Heavy Tillage/ Short Nearly Grassed Paved Areas & Type Meadow Field Pasture/ Bare Swales/ Shallow Paved Swales Lawns Ground Waterways (Sheet Flow) Conveyance 2.5 5 7 10 15 20 Calculations: Reach Slope Length 5-yr NRCS Flow Flow ID S L Runoff Convey- Velocity Time Coeff ance V Tf ft/ft ft C-5 fps minutes input input output input output output Overland 0.0020 800 0.27 N/A 0.19 71 .87 1 2 3 4 5 Sum 800 Computed Tc = 71 .87 Regional Tc = 14.44 User-Entered Tc = 14.44 IV. Peak Runoff Prediction Rainfall Intensity at Computed Tc, I = 2.56 inch/hr Peak Flowrate, Qp = 7.65 cfs Rainfall Intensity at Regional Tc, I = 6.61 inch/hr Peak Flowrate, Qp = 19.79 cfs • Rainfall Intensity at User-Defined Tc, I = 6.61 inch/hr Peak Flowrate, Qp = 19.79 cfs Calculated values for Tc & Qp are based on overide values entered for C & C-s UD-Rational v1 .02a, Tc and PeakQ 4/14/2010, 5:08 PM • CALCULATION OF A PEAK RUNOFF USING RATIONAL METHOD Project Title: Conquest C7 Site Drainage Report Catchment ID: 11 .09 Acre Project Site - UNDEVELOPED CONDITION I. Catchment Hydrologic Data Catchment ID = C7 Site Area = 11 .09 Acres Percent Imperviousness = 0.00 NRCS Soil Type = A A, B, C, or D II. Rainfall Information I (inch/hr) = C1 * P1 /(C2 + Td)AC3 Design Storm Return Period, Tr = 5 years (input return period for design storm) C1 = 28.50 (input the value of C1 ) C2= 10.00 (input the value of C2) C3= 0.786 (input the value of C3) P1 = 1 .49 inches (input one-hr precipitation--see Sheet "Design Info") III. Analysis of Flow Time (Time of Concentration) for a Catchment Runoff Coefficient, C = 0.00 Overide Runoff Coefficient, C = 0.27 (enter an overide C value if desired, or leave blank to accept calculated C.) 5-yr. Runoff Coefficient, C-5 = 0.00 Overide 5-yr. Runoff Coefficient, C = 0.27 (enter an overide C-5 value if desired, or leave blank to accept calculated C-5.) Illustration • overland Reach I flow LEGEND Reach 2 L) Beginning flaw Direction 4— Catchment Reach 3 Boundary id- NRCS Land Heavy Tillage/ Short Nearly Grassed Paved Areas & Type Meadow Field Pasture/ Bare Swales/ Shallow Paved Swales Lawns Ground Waterways (Sheet Flow) Conveyance 2.5 5 7 10 15 20 Calculations: Reach Slope Length 5-yr NRCS Flow Flow ID S L Runoff Convey- Velocity Time Coeff ance V Tf ft/ft ft C-5 fps minutes input input output input output output Overland 0.27 N/A 0.00 0.00 1 2 3 4 5 Sum 0 Computed Tc = 0.00 Regional Tc = 10.00 User-Entered Tc = IV. Peak Runoff Prediction Rainfall Intensity at Computed Tc, I = inch/hr Peak Flowrate, Qp = #VALUE! cfs Rainfall Intensity at Regional Tc, I = inch/hr Peak Flowrate, Qp = #VALUE! cfs III Rainfall Intensity at User-Defined To, I = inch/hr Peak Flowrate, Qp = #VALUE! cfs Calculated values for Tc & Qp are based on overide values entered for C & C-5. Copy of UD-Rational v1 .02a_5-Yr 1-Hr Event, Tc and PeakQ 4/14/2010. 5:23 PM • Appendix C Hydraulic Computations • • • Hydraulic Computations The detention pond for the proposed project is designed to detain the total runoff of 17,146 cf from the 100-year, 1-hour precipitation event. This is accomplished simply by excavating a 100-foot by 100-foot detention basin within the existing on-site detention area defined by the 4713 contour as shown on the Site Drainage Plan. The following Area-Capacity table provides the calculations used to verify that a total runoff capacity provided in the detention pond as designed is 18,511 cubic feet; well in excess of the required storage volume of 17,146 cf for the100-year 1-hour event. Detention Pond Area-Capacity Table (based on surveyed point elevations) Elevation Elevation Surface Ave. Incremental Cumulative (ft— MSL) Difference Area Surface Volume Volume (ft) (ft2) Area (ft2) (ft3) (ft3) 4712 6,400 0 0.5 8,200 4,100 4712.5 10,000 4,100 0.5 28,822.5 14,411.25 4713 47,645 18,511.25 • • b 926L-E6b (0L6) 'XEd €999-956 (01.6) XVd 6Eb3I. :8Ld Nis!o 00 0959-996 (0L6) '131 08LL-6617 (0L6) 'lel VE908 OOVa0100 'A2138a0 031ON SV :e,eoS a 33908 00 `SNI11001UOd 9 91.111S "IS 4103 'M L039 Z 69171 X09 'O'd 0103 iIadV :alga , Nb�d a T — t— — .► 3OVNIVHC1 .. i i n Sd :A8 pa)iaau0 �lIS a O v IN r SaCIALGS 831.VM cn � . 3 ±SnONOC) oV : 8 unne�a o •suo!s!nad :area 'oN :A8 paub!sea a!l!1 leaLIS (P3P2(;) stilt e(;a n WAWA° ��1l1141 111----...., 0.j (1,1110/ �, Z• 1:::_t aliZe 14 �ll 1�� •°SE'� •� ���' •;;;; 111 %.`-•..„...<..,..........,H4-0,.._ ,ii 1l,, = N 3 ,6Z,L3A N LL �\, �, r 7Qr �`"`0t�oo E cn tricot! r ,„ J JO Zip r Q, ai v •%'l O • 4I. a \ \ I v a 0 •�� ��;�f'� a• ��(,`��� LPL 12( cr*fit J 1/45-N---co 2 s �- 1 I (11 .? \ C\ \ C1 e g t • N \ c> N--0 ‘. .,, i 1 tax) \Irk c,. I ez, .74\ cis o� . i. ,` frs . ;IN 4 4 5 teSist \ I • 6 a ,\ CI \ _ 1161‘ i CP' \ , I, . 71: ' 'sots�. uTs \ . t • • 7 • I 412 • c0 I 5.5 �`Y \ ` 1 ' I O- V / °NJ ..../# k. 1 \ I y • ' \ s MC „,rd _I 4 �o •I . 0 ./ <4 w • •, cam . • \ —o Z cp o W a. A . \ • . . . Eg:1 ))),d</< c4 ! Can "‘. .--i / / \ ...- J . i ri • • • ml I W • • 111 • . et:<tie, •rfer 'set ' 0] I s /!° °3 1 rt / M ; I • 4 / • ‘1/41/4 • r a / w L [0 1 :i4a • P y v . S' • • s 15 _o E tlW T« O Ii • % ^� b t° r.)\> 2l = 'Reg frl i . I i ? 1 4 O � / O cc ra { i • �iUI ! 61 i g \ o i. t._ , L:ti 4 M W N.. . , -% k • E • ae ti 14 s, g > U aw ,. •r \ / / • • • -- - y}!4 - - f f .C • . . , • 1• • r r' v ,00'999 IA „Ts',H.0 S • Hello