Loading...
HomeMy WebLinkAbout20110082.tiff EXHIBIT Form No. OFFICE OF THE STATE ENGINEER GWS-25 COLORADO DIVISION OF WATER RESOURCES 818 Centennial Bldg.,1313 Sherman St.,Denver,Colorado 80203 1' (303)866-3581 EXST • WELL PERMIT NUMBER 284705 - APPLICANT DIV. 1 WD2 DES. BASIN MD Lot A Block: Filing: Sabdiv:EXEMPTION NO.1309-16-1 RE2266 APPROVED WELL LOCATION WELD COUNTY NE 1/4 NW 1/4 Section 16 JAVIER BARRON-SIXTOS Township 2 N Range 66 W Sixth P.M. 14494 WCR 22 DISTANCES FROM SECTION LINES FT LUPTON, CO 80621- 170 Ft from North Section Line 2550 Ft from West Section Line (303)304-2368 UTM COORDINATES(Meters,Zone:13,NAD83) CHANGEIEXPANSION OF USE OF AN EXISTING WELL Easting: Northing: ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDITIONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The Issuance of this permit does not ensure that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2,unless approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. 3) Approved for the change/expansion of use of an existing well constructed under permit no.28967-A. • 4) Approved pursuant to CRS 37-92-602(3)(b)(I)and the policy of the State Engineer dated 4123/86 under the following conditions. 5) The use of ground water from this well is limited to drinking and sanitary facilities as described in CRS 37-92-602(1)(c), for a commercial business. Water from this well shall not be used for lawn or landscape irrigation or for any other purpose outside the business building structure. 6) Production from this well is restricted to the Laramie Fox Hills aquifer. 7) The pumping rate of this well shall not exceed 15 GPM. 8) The annual amount of ground water to be withdrawn shall not exceed 0.33 acre-feet(108,600 gallons),as applied for. 9) Approved as the only well on a tract of land of 3.5 acre(s)described as Lot A,of Recorded Exemption no.1309-16-1 RE 2266,Weld County. 10) The return flow from the use of this well must be through an individual waste water disposal system of the type so that not less than 2%of the total amount of water withdrawn is returned to the same stream system in which the well is located. 11) A totalizing flow meter must be installed on this well and maintained in good working order. Permanent records of all diversions must be maintained by the well owner(recorded at least annually)and submitted to the Division Engineer upon request. 12) This well shall be constructed not more than 200 feet from the location specified on this permit. NOTE:To ensure a maximum productive life of this well,perforated casing should be set through the entire producing interval of the approved zone or aquifer indicated above. NOTICE:This permit has been approved subject to the following change:The UTM coordinate values provided with the permit application were not used and the well location was determined from placing the well location in the center of the lot. You are hereby notified that you have the right to appeal the issuance of this permit,by filing a written request 'th this office within sixty(60)days of the date of issuance,pursuant to the State Administrative Procedures Act.(See Sc on 4-4-104 through 106,C.R.S.) 1) a•to-urb I � r APPROVEDJLV jjrpl I �I�' State Engineer By Receipt No.3646567 DATE ISSUED 12-20-2010 EXPIRATIO DATE 0 fit-- C - L Hello