Loading...
HomeMy WebLinkAbout20130637.tiffBOARD OF DIRECTORS CHARLES ACHZIGER GENE STILLE GARY SIMPSON TODD BEAN ROBERT ARNBRECHT October 23, 2012 Mark Roberts 7113 WCR 86 Fort Collins, CO 80524 NORTH WELD COUNTY WATER DISTRICT Bob Gustafson, W G Architects PO Box 270788 Fort Collins, CO 80527 32825 CR 39 • LUCERNE, CO 80646 DON POSSELT, DISTRICT MANAGER P.O. BOX 56 • BUS: 970-356-3020 • FAX: 970-395-0997 www.nwcwd.org • e-mail: water@nwcwd.org RE: Meter Number 143 002, located at 7113 WCR 86, Fort Collins, CO 80524 To Whom It May Concern: North Weld County Water District provides domestic water service to the property located at 7113 WCR 86, Fort Collins, CO. The current owner of the property is Mark Roberts. The current service provides a 3/4" meter that should provide the proposed manufacturing business adequate service. The existing Water and Plant Investment Allocations each equal 1 Unit or 228,000 gallons annually without surcharge fees. Water tap/service is placed on the physical property, defined by a legal description. In case of a Recorded Exemption, the water tap shall only serve the parcel that the water tap is located on. Service shall NOT cross the legal description of one parcel to serve the other parcel, unless an easement has been recorded for the water service and has been approved by the District. The District guarantees treatment and delivery of water purchased. All water that is delivered with surcharge Is subject to water availability. Water purchased through the District shall be 70% delivery of an Acre -Foot of water (228,000 gallons), if the allotment for Colorado -Big Thompson (CBT) project water, which is determined by the Northern Colorado Water Conservancy District, is 50% or greater. North Weld County Water District will restrict the delivery as necessary when the CBT allotment is less than 50%. A portion of the Raw Water Fee is utilized by the District to construct storage reservoirs. The Plant Investment Fee pays for the infrastructure required to deliver 1 AFU (228,000 gallons). If usage exceeds the number of Plant Investments that were purchased, an additional Plant Investment Surcharge will be applied to your account. Plant Investments may be purchased to increase the amount of water to be delivered and avoid the Plant Investment Surcharge. Refer to table below for current Plant Investment Surcharge schedule. Water Surcharge Surcharge will be assessed when an account's year to date usage exceeds their annual allotment. Currently surcharge is $0.15 per 1,000 gallons. This fee is to recover the District's cost to obtain additional water rights for delivery. All water that Is delivered with surcharge Is subject to water availability. Effective 11/01/12, Water Surcharge will increase to $1.00 per Kgal. Plant Investment Surcharge When an account's year to date usage exceeds their Plant Investment Allotment (# of Equivalent Taps x 228,000 gallons), a surcharge will be assessed. The transfer of additional water will not remove this charge. Additional Plant Investments must be purchased to increase the allotment and reduce the Plant Investment Surcharges. 0 to 456,000 gallons above the Plant Investment Allotment (228,000 gallons) $3.95 per 1,000 gallons More than 456,000 gallons above the Plant Investment Allotment $1.95 per 1,000 gallons Respectfully, Leann Koons Office Assistant VICINITY MAP rort • • GOm 1. IWO ft N 1 I 54: • 1. e4' SAG!- FF/ ROJECT L€CATION • Part of the Southwest 1/4 of Section 32, Township 8 North, Range 67 West, Lot B recorded Exemption RE -51, County of Weld, State of Colorado Parcel Number 055532000032 Address: 7113 County Road 86 SO LOGIC October 11, 2012 Mark Roberts 1304 Duff Drive, #1 Fort Collins, Colorado 80524 Re: Septic System Design Proposed Shop/Manufacturing Building Lot B, Hermsen Exemption (7113 Weld County Road 86) Fort Collins, Colorado Soilogic Project # 12-1080 Mr. Roberts: Soilogic, Inc. (Soilogic) personnel have completed the septic system design you requested for your proposed shop/manufacturing building to be constructed at the above referenced address. An engineered septic system design is included with this report. A site specific percolation test was completed by Soilogic Inc. on the subject property and outlined in a report dated September 24, 2012. In summary, the materials encountered in the completed profile boring consisted of approximately 0 to 4 inches of topsoil and vegetation underlain by medium stiff to stiff/loose to medium dense brown to olive brown sandy lean clay to clayey sand. The sandy lean clay/clayey sand extended to the bottom of boring at a depth of approximately 9 feet below present site grade. Groundwater was not encountered in the completed profile boring at the time of drilling, nor when checked about 24 hours after completion of drilling. A log of the profile test hole is included with this report as boring B-3. A diagram indicating the approximate profile boring and pe4rcolation test location is also included. An average percolation rate of 20.0 minutes per inch was established in percolation test holes P -I through P-6 after presoaking. Weld County guidelines require a percolation rate in the range of 5 to 60 minutes per inch for use of a non -engineered conventional septic absorption field. The measured percolation rate meets that criterion. In addition, Weld County guidelines require that neither groundwater nor bedrock be encountered within 6 feet of the ground surface in the area of the proposed absorption field. The test Septic System Design Shop/Manufacturing Building - 7113 Weld County Road 86 Fort Collins, Colorado Soilogic # 12-1080 2 borings completed indicate the thickness of the near surface site soils is sufficient enough to meet the groundwater and bedrock separation criteria. Due to the commercial nature of the proposed structure, an engineered septic system design was completed for the facility. We understand a maximum of eight (8) full-time employees may occupy the manufacturing facility at full capacity. Using a design flow value of 20 gallons/person/day per each 8 -hour shift, a total design flow value 'Q' of 240 gallons/day can be calculated. Using a design percolation rate of 20 minutes per inch established in the near surface soils, a minimum of 22 Quick -4 Standard Infiltrators would be required in a bed configuration with a minimum septic tank capacity of 1000 gallons. Care should be taken at the time of system installation to insure Weld County requirements concerning minimum required separation distances between system components and site features and amenities are maintained. The owner should realize an on -site sewage disposal system (OSDS) is different from public sewer service and assume the responsibility for maintenance of the OSDS. The system is relatively maintenance free although periodic pumping of the septic tank will be required. Water use must be monitored so toilets and other fixtures are not allowed to continuously run. A freely running toilet can consume in excess of 1000 gallons per day. An excess of 1000 GPD can flood and irreparably harm the onsite septic system. In addition, toxic or chemically treated water plastic and other non -biodegradable materials should not be introduced into the OSDS. Sprinlder systems should not be installed or allowed to irrigate over the absorption bed area. We recommend the surface of the absorption field area be seeded after installation of the system using a dryland seed which does not require irrigation water. In addition, the absorption bed area should be mowed to maintain vegetation in the range of 6 to 12 inches in height. Septic System Design Shop/Manufacturing Building - 7113 Weld County Road 86 Fort Collins, Colorado Soilogic # 12-1080 3 We appreciate the opportunity to be of service to you on this project. If you have any questions concerning the enclosed information or if we can be of further service to you in any way, please do not hesitate to contact us. Very Truly Yours, Soilogic, Inc. Wolf von Carlo*itz, P.E. Principal Engineer SH❑P BUILDING & SEPTIC SYSTEM - 7113 WELD COUNTY R❑AD 86 F❑RT C❑LLINS, C❑L❑RAD❑ U OE U 0 --c--Cz p E z _ '-'^ .• . . . , .., . .I_ _ ......____ ... �'.. ., • /I • • a i •+-• r i �'..' D I A , • • �• • • ...,., . ...,„ \\ ; r\ ` \ , \\ \ 1 DW O 0 in BORING L❑CATION DIAGRAM ON TEST REST (IMMIj U.Z.. zzzz+z� Z..... Z. �-z zs,.t • - / Ill .'; 4 :� cZ s r 0000000 o 11 -St I ` .O -a 1 • Q II II II II II II , J. S •',.r r21 e ab w J�� 1 1 SEPTEMBER 2012 PROJECT # 12-1080 P V N a a a D 4.'m •Y ¢ i I a a a $5. ; r I as • _I LOT B - HERMSEN EXEMPTION SHOP & SEPTIC LOG OF BORING BJ FORT COLLINS, COLORADO Project* 12-1080 September 2012 SO LOGIC Sheet 1/1 Drilling Rig: CME 45 Water Depth Information Start Date 9/13/2012 uger Type: 4' CFA During Drilling None Finish Date 9/13/2012 Hammer Type: Automatic er Drilling None Surface Elev. - Field Personnel. DJD 4 Hours After Drilling None r u81 Eettmated Swell % Passing inSOIL DESCRIPTION Depth E "N" MC DD y,% Swell 0 Pressure Atterberg Limits f 200 Sieve (R) B ?Al (Pcf) (Psi) 500 psf (psi) LL PI (%) 0 - C VEGETATION B TOPSOIL r - 1 • • CL -SC SANDY LEAN CLAY to CLAYEY SAND 4 varies - 5 brovm, olive, rust medium stiff to tin/ • loose to medium dense 8 7 8 9 BOTTOM OF BORING 9.V • 10 11 12 13 10 • 15 18 17 18 19 20 21 22 23 24 25 OCTOBER 2012 PROJECT # 12-1080 SEPTIC SYSTEM DESIGN SO LOGIC DESIGN CALCUU110NS NanafeeWNp &Aeon w/ 6 Empor.w (ral Mr.) 6 Emplo$44 0 20 0/d - 100 9/4 0 e 240 0/d �-• (0• Jr' 13)/3.3 - 300 of (t. 20m/I) SOX Reduction with use of Graven S)•tsms - 200 sf 200 wf / 9.2 sf/e#emer (Standard oulk-4) . 22 snorkels (Gad) Upslope to Building 4"diaPVC L— Distribution Box Standard Quick -4 InfBtrator Units 4 Rows of 6 Unite\ / i 1 l 24 Septic Tank (1000 Gal) 4" dio PVC Enter Top Port ABSORPTION SYSTEM NOT TO SCALE I-4' Topsoil — Seeded Slops Standard Oulak-4 Infiltrator unit. Natural Site Soils Section 7113 WELD COUNTY ROAD 86 SHOP BUILDING rnoT nni I Iklc rni no A nn Hello