HomeMy WebLinkAbout20132934.tiffMEMORANDUM TO: Chris Gathman, Planning Services DATE: August 29, 2013 FROM: Jennifer Petrik, P.E., Public Works Department SUBJECT: USR13-0042, AKA Energy Group A Use by Special Review permit for upgrade of a gas plant The Weld County Public Works Department has reviewed this proposal. This project falls under the Use by Special Review Standard, Weld County Code, Chapter 23, Article II, Division 4, Section 23. Staff comments made during this phase of the Use by Special Review process may not be all-inclusive, as other issues may arise during the remaining application process. COMMENTS: CR 40 is a local gravel road and requires a 60 -foot right-of-way at full build out. There is presently a 60 - foot right-of-way. This road is maintained by Weld County. Pursuant to the definition of SETBACK in the Weld County Zoning (23-1-90), the required setback is measured from the future right-of-way line. The ADT on CR40 in 2012 was 255. The application materials indicated there will be 6 employees per day and 2 additional employees twice per month that access the site. 1 water truck will access the site 8 times per week. An access permit has been submitted for this project. Please provide the following additional information for the new access application. Fee of $75, photos left right and into the site. Photos left and into the site were submitted, however no photo was provided looking right. When feasible, there shall be no net increase in the number of accesses to a public road (Sec. 24-8-40). The site currently has 1 access. The request for an additional access will be reviewed by the Traffic Engineer. Please label the approved access on the plat with approved access permit number once provided. Show on the plat 60ft radii access adequate for large turning trucks. An alternative tracking control may be considered for this site. Surface must be a well drained, well maintained all weather surface such as recycled asphalt, recycled concrete, or gravel to prevent mud and debris from tracking onto the county roadway. Include a typical detail in the construction drawings. An Improvements Agreement between the Applicant and the County is required for the construction phase of this project. A right of way permit is required for any work within the County right of way. A special transport permit is required for over size, or weight vehicles. Contact Permitting/Inspection agent, at (970) 304-6496, ext. 3764. A sketch plan level drainage report was submitted. For USR projects that require stormwater detention facilities a final drainage report and final construction drawings are required. Please submit a final drainage design, drainage report and construction drawings. An accepted final drainage report is required prior to recording the plat. It appears that there are proposed improvements on the eastern existing portion of the parcel. Please provide a letter from a Professional Engineer licensed in the State of Colorado indicating that the existing retention facility is adequate and meets County Code with the additional improvements or alternatively, provide a design that meets County Code requirements. Please contact Public Works development review engineer with questions at 970-304-6496 x3762. See attached USR final drainage report checklist, flow chart for USRs and flow chart for subdivisions. M:\PLANNING - DEVELOPMENT RL:VIEW —2013 Planning Referrals\USR13\USR13-00.12 AKA Encrgy\USR13-0042 AKA energy.docx REQUIREMENTS: 1. Prior to recording the plat: A. Plat shall be amended to delineate the following: 1. County Road 40 is designated on the Weld County Road Classification Plan as a local gravel road, which requires 60 feet of right-of-way at full build -out. The applicant shall delineate on the plat the existing right-of-way. All setbacks shall be measured from the edge of right-of-way. This road is maintained by Weld County. 2. Show the approved access(es) on the plat and label with the approved permit number (will be provided). B. An accepted Final Drainage Report stamped and signed by a Professional Engineer registered in the State of Colorado is required. C. An improvements and road maintenance agreement is required for the site during construction. Road maintenance including dust control and damage repair will be included. 2. Prior to Construction: A. If more than 1 acre is to be disturbed, a Weld County grading permit will be required prior to the start of construction. B. Right of way permit is required for any work within the public right of way. C. Special transport permit is required for any over size or over weight vehicles. Development Standards (notes on the plat): 1. Should noxious weeds exist on the property, or become established as a result of the proposed development, the applicant/landowner shall be responsible for controlling the noxious weeds, pursuant to Chapter 15, Articles I and II, of the Weld County Code. 2. The historical flow patterns and runoff amounts will be maintained on the site. 3. Weld County is not responsible for the maintenance of onsite drainage related features. 4. There shall be no parking or staging of vehicles on County roads. On -site parking shall be utilized. M:\PL.ANNING UEVLLOPMLNT RI VIEW1-2013 Planning Referrals\USR131USR13-0042 AKA Energy',USR13-0042 AKA energy.docx Case Name Cl r 'C/!.v't tmko Mao, r Case Number. LAIILii' 06'12- I( Date: &Pc:14 7 Weld County Public Works Use by Special Review (USR) and Site Plan Review (SPR) Drainage Report Outline The following checklist is to be utilized as guidance, and may not be all inclusive. Other concerns not included in this checklist may arise during the review process. NOTE: A HARDCOPY OF THE DRAINAGE REPORT AND CONSTRUCTION DRAWINGS MUST BE SUBMITTED TO PUBLIC WORKS FOR REVIEW. Comment Headings Included Not Included N/A All (24" report report. important shall include be original shall "I hereby Project) accordance criteria reports shall be typed on 8-1/2" x 11" paper and bound. Drawings x 36") shall be included. The drawings shall be bound within the or included within a pocket attached inside the back cover of the The report shall be a stand-alone document and therefore all reference material, supporting documents, and calculations be copied and included within the report appendix. The report shall a cover letter presenting the drainage design for review and shall prepared or supervised by an engineer licensed in Colorado. Only documents sealed in ink will be accepted. The sealed report contain a certification sheet as follows: certify that this report for the drainage design of (Insert Name of was prepared by me (or under my direct supervision) in with the provisions of the Weld County storm drainage for the owners thereof." The Drainage Report is stamped, signed, and dated by a registered P.E. licensed to practice in the State of Colorado. V' All submitted construction plan sheets are stamped, signed, and dated by a registered P.E. licensed to practice in the State of Colorado. The following items at a minimum should be discussed in the Drainage Report narrative and should be supported with maps and calculations in the Appendix. Include a copy of this checklist with the Drainage Report submittal. I. General Location and Description 1 A. Location 1. Township, Range, Section, ' -Section. 2. Local streets within and adjacent to the development. 3 Major open channels, lakes, streams, irrigation and other water resource facilities within and adjacent to proposed project site. 4 Names of surrounding developments including jurisdiction (municipalities). B. Description of Property 1. Area in acres. 2. Ground cover and soil types. 3. Major open channels and property ownership. 4. General project description. Page 1 of 5 M:\PLANNING\Kris\Procedural Guides\USR-SPR Drainage Report Checklist 6-15-12.docx Case Name: Case Number: Date: 5 Irrigation facilities and facili ownership i ormation within 200 ft. of property. 6. Groundwater characteristics (where applicable). II. Drainage Basins and Sub -Basins A. Major Basin Description 1. Reference to Weld County Master Drainage Plan(s) where applicable. 2. Major basin drainage characteristics. 3 Identification of all FEMA-defined 100 -year floodplains and floodways affecting the property. 4 On -site & offsite contours at minimum 2 -ft vertical intervals are to be included on the Drainage Report drawings. B. Sub -Basin Description 1 Historic drainage patterns on the subject property and adjacent properties. 2. Off -site drainage flow patterns and impacts on the subject property (minimum 200 ft outside property boundary, or until no further off -site contributing flow area is encountered). • t� III. Drainage Design Criteria A. Development Criteria Reference and Constraints 1. Discussion of previous drainage studies (i.e. project master plans) for the subject property that influence or are influenced by the proposed drainage design for the site. 2. Discussion of site constraints such as slopes, streets, utilities, existing structures, irrigation ditches, and the site plan impacts on the proposed drainage plan. B. Hydrological Criteria 1 Identify design rainfall amounts and source of design storm depth information, NOAA Atlas, UD&FCD maps, etc. 2 Identify design storm recurrence intervals. Reference the appropriate information in the Appendix. 3 Identify runoff calculation method(s) and any computer models. Include summaries of the routing and accumulation of flows at all identified design points for minor and major storm runoff. Reference the results in the Appendix. 4 Identify detention discharge and storage calculation methods and computer models. Reference the results in the Appendix. 5 Discuss of off -site flows will be routed around the proposed site or over the spillway for the 100-yr develooed condition. C. Hydraulic Criteria 1 Identify conveyance capacities from County references and any computer models. 2 Identify detention outlet type. Include a summary of the 100 -year water surface elevation, spillway/overflow facility. Reference the appendix for the calculations. Include summaries of the detention storage sizing and provide a stage -storage table/curve identifying water quality storage, 100- Page2of5 M:\PLANNING\Kris\Procedural Guides\USR-SPR Drainage Report Checklist 6-15-12.docx Case Name. Case Number. Date yr detention pond storage, and 1 ft of freeboard. Reference the calculations in the Appendix. 3 Identify water quality outlet configuration. Reference the calculations in the Appendix. 4 Identify culverts including diameter, type, and slope. Reference the calculations in the Appendix. 5 Identify storm sewer inlets, manholes, etc. Reference the calculations in the Appendix. 6. Discussion of permanent erosion control features. 7. Discussion and justification of criteria or calculation methods (for water quality, check dams, drop structures, rundowns, etc.) used that are not Presented in Weld County CODE. IV. Drainage Facility Design A. General Concept 1. Discussion of concept and typical on -site drainage patterns. '-- 2 Discussion of compliance with off -site runoff considerations and constraints. '' 3. Discussion of the content of all tables, charts, figures, or drawings in the report.- . 4 Discussion of anticipated hydraulic structures (channels, pipes, rundowns, etc.). i/" B. Specific Details 1 Discussion of maintenance access and aspects of the design. Include a maintenance plan. 2 _ Provide copies of CDPHE, CAFO, DRMS, or State Engineer's applications where applicable. 6ria-4-1 4 P4',, T! * permit ,:t _, x44 V. Conclusions A. Compliance with the Weld County CODE 1. Statement of whether or not the design will meet Weld County Code. B. Drainage concept 1. Effectiveness of drainage design to control damage from storm runoff. 2. Influence of proposed development on any applicable Weld County Master Drainage Plan recommendations. 3 Identification of and intent to obtain written approval of affected irrigation company or other property owner(s). Weld County may require that the applicant provide evidence that offsite impacted jurisdictions have been notified of the proposed plans. 4. Reference all criteria and technical resources utilized. The Appendices should include at a minimum the following information. The Drainage Report should be a standalone document and needs to include copies of all pertinent references used in the generation of the Drainage Report. VI. Appendices A. Hydrologic Computations -7 Page 3 of 5 M:IPLANNING\Kris\Procedural Guides\USR-SPR Drainage Report Checklist 6-15-12.docx Case Name Case Number Date 1 Vicinity Map showing location of the site in relation to surrounding area. Show the approximate boundaries of the site. 2 FIRMette showing location of the site in relation to the FEMA mapped floodplains/floodways. Show the approximate boundaries of the site. 3 Soil Survey Information/Map showing soil types and soil hydrologic groups for the project site. 4 Rainfall Maps with the project location identified. Maps can be from UDFCD or NOAA as applicable. 5. Land use assumptions regarding adjacent properties. 6. Initial and major storm runoff computations at specific design points. (5- yr, 10-yr, and 100-yr) 7. Historic and fully developed runoff computations at specific design points. 8. Computer model input and output. Include model files and/or spreadsheets on a CD-ROM to be attached to the Drainage Report. B. Hydraulic Computations 1. Culvert sizing. Provide computations showing slope, pipe size, material, invert elevations, 100 -year energy grade line (EGL,oc), and hydraulic profile. 2. Storm inlet sizing. 3 Swale or channel sizing. The calculations need to show stability calculations for unvegetated and vegetated conditions. 4 Riprap or other revetment design. The calculations need to include design for bedding and geo-fabric. 5 Pond area/volume capacity and outlet sizing. Show calculations for the 100 -year water surface elevations and overflow facilities, 6. Orifice plate, spillway, and pond outlet sizing. 7. Include computations for permanent erosion control features. 8. Any computer model input and output. Include model files and/or spreadsheets on a CD-ROM to be attached to the Drainage Report. C. 24 x 36 Maps 1. Historic Drainage Basin Map. Show drainage basin boundaries (on -site and off -site), 2 ft on -site and off -site drainage boundaries, design points, historic flow path, flow path length, and flow path slope. 2 Fully Developed Drainage Basin Map. Show drainage basin boundaries (on -site and off -site), 2 ft on -site and off -site drainage boundaries, design points, developed flow path, flow path length, and flow path slope. Show drainage easement including metes and bounds description around all drainage related features. Show any other drainage easements that may exist on the project site. 3. Cgnstru awin_gs showing location, sizing, and details for all storm sewers, open channels, culverts, cross -pans, and other appurtenances. Include cross sections of swales and open channels. 4. Construction Drawings showing location of detention facilities and outlet works. Include the 100 -year water surface elevations, overflow facilities, and labels for pond volume and discharge. ..- ‘,,,- 5 Grading Plan showing existing and proposed contours. Identify the lowest opening elevation of buildings showing that they are above the 100 -year water surface elevations of channels, swales, streets, ponds, or other drainage facilities. 6 Erosion and Sediment Control Plan showing all BMPs to be utilized on - site. Include typical installation details, installation notes, and maintenance notes for all BMPs to be utilized on the project site. Page 4 of 5 M:\PLANNING\Kris\Procedural Guides\USR-SPR Drainage Report Checklist 6-15-12.docx Case Name Case Number Date: 7 Detail sheets for pond outlet, orifice plate, trash rack, spillway configuration, riprap, culverts, channels, etc. 8. All culverts are to be identified and profiled in the Construction Drawings with slope, pipe size, material, invert elevations. 100 -year energy grade line (EGL,og), and hydraulic profile. , 9 On all Construction Drawings show the location of all existing and proposed utilities and identify the utility as existing or proposed. 10. The elevations of manhole and inlet inverts are identified and profiled. 11 Miscellaneous hydraulic structures/features are shown on the Construction Drawings. Page 5 of 5 M:\PLANNING\Kris\Procedural Guides\USR-SPR Drainage Report Checklist 6-15-12.docx Development Drainage Guide — USR/MUSR/SPR DRAFT if c . Weld Count Public Wotk1.111 115t. Greeley. CO 80637 970.304.6496 Is this a "Use by Right"? Pre -App Meeting Determination if Full Drainage Report is required. (Site and project dependant) Is Full Drainage Report �N required? N.Nez Y S to discuss any potential unique on - site or off -site issues that may require a variance iimpimma Use the USR/SPR drainage report checklist to develop the DR and drainage related construction drawings. (Water Quality design is included in checklist) 7/9/2013 NO Water Quality Feature and drainage narrative (PE stamp not requ red) project in an MS4 NaNrear) v E$ Submit Complete application with Water Quality Feature and drainage narrative Stamped by PE application Final Drainage Report and drainage related construction drawings (or preliminary if applicable) Stamped by PE Submit a preliminary drainage report to scope the scale of the drainage prior to final plans. Be aware. this adds an additional step and additional design and review time to the process (PC, US, (Not required for SPR and some MUSR) Address co of approval (IA, final DR if preliminary and final stamped by PE) Modify submittal, address comments Grading Permit Construction Legend BOCC=Board of County Commissioners DR=Drainage Report IA=Improvements Agreement MUSR=Minor Amendment of Use by Special Review PC=Planning Commission PE=Professional Engineer SPR= Site Plan Review UB=Utility Board USR=Use by Special Review Development Drainage Guide — Subdivisions DRAFT wv4w.ca.weld.co.us, Weld County Public Works L111 ti St. Greeley. CO 8CG32 97C-304.6496 a Is this a "Use by Right ' "? Y:S Determination if project is a subdivision Contact Public I Works to discuss any potential unique on -site or ----> off -site issues that may require a variance 1) Sketch Plan (30%) 2) Change of zone (80% ) 3) Final plat (100%) Each stage has a DR checklist. These are progressive Administrative approval/denial Pr Change of Zone DR submittal (use Change of Zone checklist) 28 day referral review Hearings: PC, BOCC'' (Determination of specific or conceptual design) Finalat DR submittal _{, (use Final Plat checklist) Ad ress conditions of approval (IA, final DR if preliminary and final stamped by PE) Modify submittal, address comments 7/9/2O13 28 day referral review_ Record Plat - bncep ua rPC. U BOCC 1 Specific: UB, Administrative I Legend BOCC=Board of County Commissioners DR=Drainage Report IA=Improvements Agreement MUSR=Minor Amendment of Use by Special Review PC=Planning Commission PE=Professional Engineer PUD=Planned Unit Development SPR= Site Plan Review UB=Utility Board USR=Use by Special Review TO: FROM: SUBJECT: DATE: MEMORANDUM Chris Gathman, Planning Services Lauren Light, Environmental Health USR13-0042 AKA Energy Group, LLC 10/15/2013 Environmental Health Services has reviewed this proposal for a Site Specific Development Plan and Amended Use by Special Review Permit for Mineral Resource Development Facilities including an Oil and Gas Support and Service Facility (expansion of an existing Gas Processing Facility originally approved under USR-866) in the A(Agricultural) Zone District. The application states the facility will have 6 full time employees. Central Weld Water District provides water. There is a septic system located on the adjacent facility (SP - 0100156) which is sized for 4 people. The application indicates the system will be inspected by an engineer to determine if the system is adequate for additional employees. The waste handling plan stipulates that refuse will be removed by Waste Management. The plan includes a list of types and quantities of chemicals to be stored on site. Procedures for cleanup and disposal of spilled hazardous materials will be included in AKA Energy Groups Spill Prevention Control and Countermeasure plan (SPCC). The plan shall be available on site at all times. On site dust will be controlled by graveling the site. We have no objections to the proposal; however, we do recommend that the following conditions be part of any approval: We recommend that the following requirements be met prior to allowing the plat to be recorded: 1. The applicant shall submit evidence of an Air Pollution Emission Notice (A.P.E.N.) and Emissions Permit application from the Air Pollution Control Division, Colorado Department of Health and Environment to Environmental Health Services Division of the Weld County Department of Public Health & Environment. Alternately, the applicant can provide evidence from the APCD that they are not subject to these requirements. 2. In the event the applicant intends to utilize the existing septic system the septic system shall be reviewed by a Colorado Registered Professional Engineer. The review shall consist of observation of the system and a technical review describing the systems ability to handle the proposed hydraulic load. The review shall be submitted to the Environmental Health Services Division of the Weld County Department of Public Health and Environment. In the event the system is found to be inadequately sized or constructed the system shall be brought into compliance with current Regulations. We recommend that the following requirement be incorporated into the permit as a condition that must be met one month prior to operation: 1. A signed copy of the Spill Prevention, Control and Countermeasure Plan shall be provided to Environmental Health Services Division of the Weld County Department of Public Health & Environment. We recommend that the following requirements be incorporated into the permit as development standards. 1. All liquid and solid wastes (as defined in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended) shall be stored and removed for final disposal in a manner that protects against surface and groundwater contamination. 2. No permanent disposal of wastes shall be permitted at this site. This is not meant to include those wastes specifically excluded from the definition of a solid waste in the Solid Wastes Disposal Sites and Facilities Act, 30-20-100.5, C.R.S., as amended. 3. Waste materials shall be handled, stored, and disposed in a manner that controls fugitive dust, blowing debris, and other potential nuisance conditions. The applicant shall operate in accordance with the approved "waste handling plan", at all times. 4. Fugitive dust and fugitive particulate emissions shall be controlled on this site. The facility shall be operated in accordance with the approved "dust abatement plan", at all times. 5. Adequate drinking, handwashing and toilet facilities shall be provided for employees and patrons of the facility, at all times. 6. Sewage disposal for the facility shall be by septic system. Any septic system located on the property must comply with all provisions of the Weld County Code, pertaining to Individual Sewage Disposal Systems. 2 7. All potentially hazardous chemicals must be handled in a safe manner in accordance with product labeling and in a manner that minimizes the release of hazardous air pollutants (HAP's) and volatile organic compounds (VOC's). All chemicals must be stored secure, on an impervious surface, and in accordance with manufacturer's recommendations. 8. The Spill Prevention, Control and Countermeasure Plan shall be available on site, at all times. 9. The operation shall comply with all applicable rules and regulations of State and Federal agencies and the Weld County Code. 3 Department of Planning Services 1555 N 17th Ave Greeley, CO 80631 (970) 353-6100 Weld County Referral Date: August 3, 2013 Applicant: AKA Energy Group, LLC Project: A Site Specific Development Plan and Amended Use by Special Review Permit for Mineral Resource Development Facilities including an Oil and Gas Support and Service Facility (expansion ofan existing Gas Processing Facility originally approved under USR-866) in the A(Agricultural) ZoneDistrict. Case Number: USR13-0042 Parcel Number: 105732200006 After reviewing the application for a expansion of an existing Gas Processing Facility originally approved under USR-866 A building permit will be required for any new construction, alteration, or addition to any buildings or structures on the property. A building permit application must be completed and two complete sets of engineered plans including engineered foundation plans bearing the wet stamp of a Colorado registered architect or engineer must be submitted. A geotechnical engineering report performed by a registered State of Colorado engineer shall be required or a open hole inspection. Buildings, equipment and structures shall conform to the requirements of the various codes adopted at the time of permit application. Currently the following has been adopted by Weld County: 2012 International Building Code; 2012 International Mechanical Code; 2012 International Plumbing Code: 2012 International Energy Code; 2006 International Fuel Gas Code; 2011 National Electrical Code; 2009 ANSI 117.1 Accessibility Code the 2012 International Plumbing Code. and Chapter 29 of the Weld County Code. A plan review shall be approved and a permit must be issued prior to the start of construction. All building requirements can be found on the Weld County web -site www.co.weld.co.us/planning department/building inspection/permits Frank Piacentino Department of Building Inspection Submit by Email Weld County Referral August 01, 2013 The Weld County Department of Planning Services has received the following item for review: Applicant: AKA Energy Group, LLC Case Number: USR13-0042 Please Reply By: August 29, 2013 Planner: Chris Gathman Project: A Site Specific Development Plan and Amended Use by Special Review Permit for Mineral Resource Development Facilities including an Oil and Gas Support and Service Facility (expansion of an existing Gas Processing Facility originally approved under USR-866) in the A(Agricultural) Zone District. Location: South of and adjacent to County Road 40 and 0.5 miles west of County Road 29. Parcel Number: 105732200006 Legal: Part of Lot C of Recorded Exemption RE -4508; located in Part of the NW4 of Section 32, T4N, R65W. of the 6th P.M., Weld County, Colorado. Parcel Number: 105732200005-R5217208 Legal: PT LOT C REC EXEMPT RE -4508; PT NW4 Section 32, T4N, R66w of the 6th P.M., Weld County, Colorado. The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. We have reviewed the request and find that it does / does not comply with our Comprehensive Plan because: We have reviewed the request and find no conflicts with our interests. See attached letter. Signature Agency Roy Rudisill Weld OEM Date 8 13.13 Weld County Planning Dept 1555 N 17th Ave, Greeley, CO 80631 (970) 353-6100 ext.3540 (970) 304-6498 fax Interoffice Memo To: Chris Gathman From: Roy Rudisill Date: August 14, 2013 Subject: USR13-0042 Chris, I completed my review of the list request for aka Energy Group, LLC. Aka Energy Group is currently reporting to the LEPC and they are in good standing. I would request that they provide updated information when the facility is completed and report any increases in hazardous material storage. I would also request that they meet with the fire district representatives and make sure they have a good understanding of response needs for the updated / new facility. Roy Rudisill Weld OEM Weld County Referral August 01, 2013 The Weld County Department of Planning Services has received the following item for review: Applicant: AKA Energy Group, LLC Case Number: USR13-0042 Please Reply By: August 29, 2013 Planner: Chris Gathman Project: A Site Specific Development Plan and Amended Use by Special Review Permit for Mineral Resource Development Facilities including an Oil and Gas Support and Service Facility (expansion of an existing Gas Processing Facility originally approved tinder USR-866) in the A(Agricullural) Zone District. Location: South of and adjacent to County Road 40 and 0.5 miles west of County Road 29. Parcel Number: 105732200006 Legal: Part of Lot C of Recorded Exemption RE -450B; located in Part of the NW4 of Section 32, T4N, R65W. of the 6th P.M.. Weld County, Colorado. Parcel Number: 105732200005-R5217208 Legal: PT LOT C REC EXEMPT RE -4508; PT NW4 Section 32, T4N, R66w of the 61h P.M., Weld County, Colorado. The application is submitted to you for review and recommendation. Any comments or recommendation you consider relevant to this request would be appreciated. Please reply by the above listed date so that we may give full consideration to your recommendation. Any response not received before or on this date may be deemed to be a positive response to the Department of Planning Services. If you have any further questions regarding the application, please call the Planner associated with the request. Please note that new information may be added to applications under review during the review process. If you desire to examine or obtain this additional information, please call the Department of Planning Services. 0 We have reviewed the request and find that it does/ dons not comply with our Comprehensive Plan because: We have reviewed the request and find no conflicts with our interests. See attached letter. Signature Agency lZ Date 2 Weld County Planning Cep). 1555 NI 178, Ave, Greeley, CO. 80831 (970) 3534100 ex) 3590 (970) 304-6198 tax Platteville/Gilcrest Fire Protection District August 18, 2013 Comments on referral for USR13-0O42 To Whom rt May Concern: In December of 2O12, Mr. Szabo informed me that AKA was looking at expanding their current operation on WCR 40. Once plans for the project are available, I will need a copy and will be meeting with Mr. Szabo again. Nothing else further at this time is required. Sincerely, Russell Kissler Lieutenant 303 Main Street, P.O. Box 407 • Platteville, CO 80651 • 970-785-2232 • Fax 970-785-0139 215 Main Street,1&O Box 43 • Gilcrest, CO 80623 • 970-737-2966 • Fax 970.737-9006 Hello