Loading...
HomeMy WebLinkAbout20131437.tiffPhase II Drainage Amendment Memo PATRICK ENGINEERING Pawnee Water Management Groundwater Load �ut & Recycling Facility Weld County. CO I it Prepared for Halliburton 1125 17th Street, Suite 1900 Denver, CO 80202 Patrick Project Number 21273.003 Date Prepared: May 2011 Revised: February 2012 Amended: November 2012 Partnering to Build Better Infrastructure 1400 West 122°d Avenue Suite 102 Westminster Co. 80234 : info,* patricken inecrin;.1.com : www.patrickengineering.com PHASE II DRAINAGE AMENDMENT MEMO WELD COUNTY, CO PAWNEE WATER MANAGEMENT GROUNDWATER LOAD OUT & RECYCLING FACILITY USE BY SPECIAL REVIEW USR-1787 PREPARED FOR: Halliburton 1125 17th Street, Suite 1900 Denver, CO 80202 PREPARED BY: Patrick Engineering Inc. 1400 West 122nd Avenue Suite 102 Westminster, Co. 80234 DATE: May 6, 2011 REVISED: February 27, 2012 AMENDED: November, 2012 Pawnee Water Management USR-1787 — Major Amendment Phase II Drainage Amendment Memo TABLE OF CONTENTS Page 1.0 BACKGROUND INFORMATION 1 2.0 DRAINAGE FACILITY DESIGN 2 Direct Discharge Area Updated Water Quality Pond & Contributing Area for Phase I Sub -basin D -1A Water Quality Swale & Contributing Area for Phase II Sub -basin 0-1B Maintenance LIST OF TABLES Table 1 — Updated D -1A Water Quality Capture Volume Table 2 — D-1 B Water Quality Capture Volume APPENDICES Appendix A Drainage Calculations LIST OF FIGURES Figure 1 Phase II Developed Drainage Plan REFERENCES 1) "Weld County Storm Drainage Criteria Addendum to the Urban Storm Drainage Criteria Manuals Volumes 1, 2, and 3", by Weld County Public Works Department, October 2006. 2) Weld County Code, Section 24-7-120 3) Web Soil Survey 2.0, National Cooperative Soil Survey, Weld County, Colorado, Southern Part United States Department of Agriculture, Natural Resources Conservation Service http://websoilsurvev.nrcs.usda.dov 4) Urban Storm Drainage Criteria Manual, Volumes 1, 2. and 3 Urban Drainage and Flood Control District Patrick Engineering Inc. November 2012 Pawnee Water Management USR-1787 — Major Amendment Phase II Drainage Amendment Memo 1.0 BACKGROUND INFORMATION Pawnee Water Management has submitted a major amendment to the Use by Special Review (USR) permit #1787 to the Weld County Department of Planning Services to construct and operate a process water recycling facility directly adjacent to the Phase I Water Load Out Facility. The intent of the recycling facility is to allow for water recovered from oil and gas processes to be treated and reused. In addition, the facility will provide an injection well for disposal of treated water. This Drainage Amendment Memo provides Phase II drainage design information and is intended to amend the Phase I Drainage Design that was approved by Weld County Public Works Department in early spring of 2012. Design requirements suggested by Weld County for the Phase I facility were implemented in a similar method in the separate Phase II design. 2.0 DRAINAGE FACILITY DESIGN The drainage plan developed for the entire water load out and treatment facility is divided into four sub -basins. Sub - basin D -1A includes Phase I construction of the Water Load Out Facility, D-1 B consists of Phase II development of the Recycling Facility, D -1C includes the secondary containment portion of the recycling facility, and H -1A incorporates the remaining undeveloped parcel. Both phases of construction have a separate Water Quality feature to temporarily detain and treat stormwater runoff from that portion of the facility. Sub -basin H -1A, which comprises almost entirely of undeveloped native grassland is allowed to continue to sheet flow from the site as in its historic condition. (Please refer to Figure 3 Developed Drainage Plan). Direct Discharge Area Sub -basin H -1A covers 67.4 acres and is the remaining portion of the historical H-1 basin. 99% of this sub -basin is the historical undeveloped grasslands that will continue to flow undetained from the site via the historical drainage pattern. A portion of basin H -1A contains a small amount of aggregate drive surface from Phase 1 work and grassed fill slopes that are unable to drain towards the water quality pond and will be released along with the rest of the basin. Since this amount of aggregate surface is approximately 1% of the basin, the flows are not anticipated to affect the overall stormwater quality or rates leaving the site. Two grassed diversion swales to the north and south of the site will divert surface water around the site. The shallow grassed swale to the north of the site is to be extended to the east about 460 linear feet to account for regrading of the additional truck parking and storage area. This diversion swale continues to be routed through a 12" HDPE culvert under the as -built access drive and daylights to existing ground on the south side of the drive. The diversion swale proposed to the east and south of the site will divert water towards the existing shallow swale near County Road 95. The proposed trapezoidal swales have a minimum depth of 1 -ft and a bottom width of 2 -ft (northern swale) and 4 -ft (southern swale) in order to contain and appropriately convey any flows that collect from above the site. Updated Water Quality Pond & Contributing Area for Phase I Sub -basin D -1A The existing load out facility, delineated by Sub -basin D -1A, consists of an existing 3.29 acres of aggregate pavement, 0.52 acres of concrete for truck loading and 3.56 acres of native grassed area. These areas all drain, overland, into the Phase I Water Quality pond located at the center of the facility. Patrick Engineering Inc. 1 November 2012 Pawnee Water Management USR-1787 — Major Amendment Phase II Drainage Amendment Memo 1.0 BACKGROUND INFORMATION Pawnee Water Management has submitted a major amendment to the Use by Special Review (USR) permit #1787 to the Weld County Department of Planning Services to construct and operate a process water recycling facility directly adjacent to the Phase I Water Load Out Facility. The intent of the recycling facility is to allow for water recovered from oil and gas processes to be treated and reused. In addition, the facility will provide an injection well for disposal of treated water. This Drainage Amendment Memo provides Phase II drainage design information and is intended to amend the Phase I Drainage Design that was approved by Weld County Public Works Department in early spring of 2012. Design requirements suggested by Weld County for the Phase I facility were implemented in a similar method in the separate Phase II design. 2.0 DRAINAGE FACILITY DESIGN The drainage plan developed for the entire water load out and treatment facility is divided into four sub -basins. Sub - basin D -1A includes Phase I construction of the Water Load Out Facility, D-1 B consists of Phase II development of the Recycling Facility, D -1C includes the secondary containment portion of the recycling facility, and H -1A incorporates the remaining undeveloped parcel. Both phases of construction have a separate Water Quality feature to temporarily detain and treat stormwater runoff from that portion of the facility. Sub -basin H -1A, which comprises almost entirely of undeveloped native grassland is allowed to continue to sheet flow from the site as in its historic condition. (Please refer to Figure 3 Developed Drainage Plan). Direct Discharge Area Sub -basin H -1A covers 67.4 acres and is the remaining portion of the historical H-1 basin. 99% of this sub -basin is the historical undeveloped grasslands that will continue to flow undetained from the site via the historical drainage pattern. A portion of basin H -1A contains a small amount of aggregate drive surface from Phase 1 work and grassed fill slopes that are unable to drain towards the water quality pond and will be released along with the rest of the basin. Since this amount of aggregate surface is approximately 1% of the basin, the flows are not anticipated to affect the overall stormwater quality or rates leaving the site. Two grassed diversion swales to the north and south of the site will divert surface water around the site. The shallow grassed swale to the north of the site is to be extended to the east about 460 linear feet to account for regrading of the additional truck parking and storage area. This diversion swale continues to be routed through a 12" HDPE culvert under the as -built access drive and daylights to existing ground on the south side of the drive. The diversion swale proposed to the east and south of the site will divert water towards the existing shallow swale near County Road 95. The proposed trapezoidal swales have a minimum depth of 1 -ft and a bottom width of 2 -ft (northern swale) and 4 -ft (southern swale) in order to contain and appropriately convey any flows that collect from above the site. Updated Water Quality Pond & Contributing Area for Phase I Sub -basin D -1A The existing load out facility, delineated by Sub -basin D -1A, consists of an existing 3.29 acres of aggregate pavement, 0.52 acres of concrete for truck loading and 3.56 acres of native grassed area. These areas all drain, overland, into the Phase I Water Quality pond located at the center of the facility. Patrick Engineering Inc. 1 November 2012 Pawnee Water Management USR-1787 — Major Amendment Phase II Drainage Amendment Memo Due to site grading, the construction of Phase II, as well as additional truck parking and a screened storage area, another 0.658 acres of aggregate pavement must be added to sub -basin D-1 A. Recalculation of the Water Quality Pond Volumes indicates that the additional aggregate surfaces contributing to the pond will raise the Water Quality surface elevation by only 0.04 ft. This amount is considered insignificant and there shall be no changes required to the approved and as -built Phase I structures. The updated information for the as -built water quality pond is in Table 1. The existing pond contains 2,900 cubic feet of sedimentation storage and 16,500 cubic feet of Water Quality Volume. Table 1 — D -1A Water Quality Capture Volume: Area (Acres) Average Impervious (%) WQCV Depth (in) Required WQCV (Cu. Ft.) WQ Elev (ft) Phase I Design 8.962 28 0.13 5146 5047.16 Final Design 9.621 29.2 0.13 5620 5047.20 24 -hr drain time: WQCV = 0.9*(0.91 i3 —1.19i2+0.781) Release of the WQCV will occur in a period of 24 hours via a 2 3/4 inch diameter orifice over a 4 inch diameter pipe. The 4 inch pipe was selected to provide a rigid outlet through the outlet works. A trickle channel made up with high evaporative grasses is used to channel low flows into the outlet works. Water Quality Swale & Contributing Area for Phase II Sub -basin D -1B The proposed 4.1± acre Phase II recycling and storage facility, delineated by Sub -Basin D-1 B, contains two drainage areas. The first drainage area is 1.77 acres and contains 1.48 acres of gravel drive aisles and 0.29 acres of grassed fill slopes around the facility. Stormwater from the gravel surfaces will sheet flow towards the southwest corner of the site, to be collected in two 4 foot wide vegetated collection swales. These swales will convey the stormwater to a 4 foot wide, 1 foot deep, 1,200 cubic foot water quality swale located at the southwest edge of the facility for temporary storage and treatment. The outlet shall be a 3 foot wide broad -crested concrete weir that will allow treated stormwater to be released over a 24 -hour period. Any excess storm runoff greater than the design WQCV will also be released by the weir outlet structure, which has been designed to discharge larger flows if necessary. The second drainage area is 1.94 acres and consists of a self-contained area located in the center of the sub -basin. This area includes the 1.74 acre contained area which surrounds the wastewater recycling equipment and storage tanks as well as 0.20 acres of concrete pads for truck loading and unloading that drain into the containment area to collect hose water and any other spill falling on the concrete. Storm water that also falls on these areas will be collected by shallow diversion swales and 4" HDPE drain pipes, then either pumped through the recycling facility for treatment internally or pumped directly into the injection well for disposal. The proposed water quality swale contains 1200 cubic feet of Water Quality Volume. The Water Quality Capture Volume (WQCV) was calculated per Table 2. Table 2 — D-1 B Water Quality Capture Volume: Area (Acres) Average Impervious (%) WQCV Depth (in) Required WQCV (Cu. Ft.) 1.77 34 0.15 1128 Patrick Engineering Inc. 2 November 2012 Pawnee Water Management USR-1787 — Major Amendment Phase II Drainage Amendment Memo 24 -hr drain time: WQCV = 0.9*(0.91 i3—1.19i2+0.78i) Release of the WQCV will occur in a period of 24 hours via a rip rap protection 3ft wide concrete weir located at the south west corner (center) of the water quality swale. This weir will also be designed to release any storm runoff greater than the WQCV design storm. Maintenance All areas of the 12.5± acre developed site are accessible for maintenance. Maintenance on the recycling systems and pumps for the water treatment and internal stormwater collection will be periodically checked by full-time staff. The Phase II water quality swale and outlet weir shall be inspected periodically for erosion rills and sediment build-up in the riprap. The perimeter swales will also require occasional maintenance and inspections. The drainage facilities for this site have been designed in the full knowledge that Weld County will not be responsible for the maintenance of drainage -related facilities. All drainage facilities are the solely the responsibility of the owner. Patrick Engineering Inc. 3 November 2012 APPENDIX A Drainage Calculations PATRICK ENGINEERING JOB NO. 21273.003 DATE 11/9/2012 PROJECT Pawnee Water Management - Wastewater Recycling Facility REVISION DATE Runoff Coefficients - Developed Weighted Coefficients (Type "B" Soil) BASIN LAND USE PHASE I AREA (ac.) PHASE II AREA (ac.) C2 O5 O10 C100 I(%) H -1A Natural Grasses 70.894 66.531 0.00 0.08 ' 0.17 0.36 2 Gravel Road 0.871 0.871 0.23 0.30 0.36 0.50 40 Total Area 71.765 67.402 Composite 0.00 0.08 0.17 0.36 2.5 BASIN LAND USE PHASE I AREA ac. PHASE II AREA ac. C2 O5 O10 C100 I(%) D -1A Gravel Road 4.882 5.54 0.23 0.30 0.36 0.50 40 Natural Grasses 3.557 3.56 0.00 0.08 0.17 0.36 2 Concrete 0.523 0.52 0.89 0.90 0.92 0.96 100 Total Area 8.962 9.621 Composite 0.18 0.25 0.32 0.47 29.2 BASIN LAND USE PHASE I AREA (ac.) PHASE II AREA (ac.) . C2 . C5 O10 C100 l(%) D-1 B Total Area Natural Grasses - 0.291 0.00 0.08 0.17 0.36 2 Gravel Road - 1.477 0.23 0.30 0.36 0.50 40 1.769 Composite 0.19 0.26 0.33 0.47 33.7 BASIN LAND USE PHASE I AREA (ac.) PHASE II AREA (ac.) C2 C5 O10 C100 I(%) D-1 C Concrete - 0.199 0.890 0.900 0.920 0.960 100 Containment Area - 1.736 0.890 0.900 0.920 0.960 100 Total Area - 1.936 Composite 0.89 0.90 0.92 0.96 100.0 Basin D-1 A Water Quality Capture Volume AREA AVE IMP. WQCV WQCV 10-YR 100-YR (ACRES) (°/0) (Inches) (C.F.) (C.F.) (C.F.) 9.62 29% 0.13 5620.2 14,256 28,846 AREA AVE IMP. Basin (ACRES) (%) D-1 B WQCV WQCV (Inches) (C.F.) 1.77 34% 0.15 1127.8 24 -hr drain time: WQCV = 0.9`(0.91 i3 -1.19i2+0.781) C3 PATRICK ENGINEERING JOB NO. 21273.003 DATE 11/9/2012 PROJECT Pawnee Water Management - Wastewater Recycling Facility REVISION DATE WATER QUALITY VOLUME PROVIDED WATER QUALITY SWALE LPHASE II) STAGE CUM. WQCV CONTOUR AREA VOLUME VOL. ELEV. 5047.0 0 0 1220 5047.92 5048.0 2440 1220 *Storage Volume calculated using the the average -end area formula: V1,2 = [(A, +A2)/2jd MINOR WEIR WQ VoI= 1,127.8 10-yr VoI= 0 100-yr Vol= 0 WQ W.S.= 5047.92 *10-yr W.S.= 100-yr W.S. = Q(wiER) = C(L-0.1 iH))H^3/2 Q(w1ER) = C(L-0.1 iH))H"3/2 = 0.43 cfs C = 3.330 L = 3.0 H= 0.12 i= 2 Spillway Elev: 5047.8 WQ WS Elev: 5047.92 PATRICK ENGINEERING JOB NO. 21273.003 DATE 11/9/2012 PROJECT Pawnee Water Management - Wastewater Recycling Facility REVISION DATE WATER QUALITY VOLUME PROVIDED WATER QUALITY POND (PHASE IZ STAGE CONTOUR AREA VOLUME CUM. VOL. ELEV. WQCV 5046.0 0 5047.0 5048.0 5048.5 5845 21163.5 37903 2923 13504 14767 0 2923 16427 31193 *Storage Volume calculated using the the average -end area formula: V, 2 = ((A, +A2)/2]d 5047.20 WQ VoI= 5,620.2 10-yr VoI= 18,412 100-yr Vol= 26,200 WQ W.S.= 5047.20 *10-yr W.S.= 100-yr W.S. = OUTLET STRUCTURE ORIFICE CALCULATIONS Q100 = C*A * ((2*g*H)^.5) A = 1/4(rrD2) H10 = Elev,o - Eleywocv+D10/2 H100 = Elev,00 - EleviNv+D,00/2 WQCV Orifices WQ Discharge: Centroid: Discharge Coeff: Orifice Area: Diameter: (24 -hour drain time) 0.065 cf/s 0.10 ft 0.6 0.043 6.16 2.80 sf si in Q,o = 2.04 cfs 4,00 = 5.91 cfs EIev,Nv = 5047.00 ft Elevwocv = 5047.20 ft Elev10 = 0.00 ft Elev1oo = 0.00 ft Q = WQVol / 24hr drain time Centroid = (WQ Surface - Invert out) / 2 (Bently Flowmaster suggested) A0 = Q / Cd*(2*q*H)^2 - > USE 2 3/4" ORIFICE Worksheet for Broad Crested Weir - 1 Project Description Solve For Input Data Headwater Elevation Crest Elevation Tailwater Elevation Crest Surface Type Crest Breadth Crest Length Results Discharge Headwater Height Above Crest Tailwater Height Above Crest Weir Coefficient Submergence Factor Adjusted Weir Coefficient Flow Area Velocity Wetted Perimeter Top Width Discharge Gravel 5047.92 ft 5047.80 ft 5047.00 ft 3.00 ft 3.00 ft 0.32 ft/s 0.12 ft -0.80 ft 2.55 US 1.00 2.55 US 0.36 ft2 0.88 ft/s 3.24 ft 3.00 ft Bentley Systems, Inc. Haestad Methods StIepakt. vIaster V8i (SELECTseries 1) (08.11.01.03] 11/8/2012 3:57:18 PM 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 FIGURES •M•1 1 •wo ••n =mom am =maw incle .nrsarow 7w ms i1•••r!•1 ••• n. NOItl1Nd LBL 4-HSfl NVId 3OVNIVUO O3d013A30 NOINIEI 7VN s 8 Y 22 Q) MUMMA inOOVO1ULLVMONnOO LN3w3OVNVw MINN 33NMVd I E e I I A4'ZOLZ M.Btd.S.69S A2NONnosusn 41 iJ AZ l9El M.9I,1S.69S kti .11•S4Et 3LOAE.6BS i I I AavaNnoa n - - - _ 8.612 IOM NOO°25'33'E 2615.53' DCAINA,;E LE: DRAINAGE PLAN NOTES: Hello